Early Outcomes of Harmony Transcatheter Pulmonary Valve Implantation in the Middle East: A Single-Center Experience From Saudi Arabia.
Abdullghany M Dowaikh, Amr A Arafat, Sameh F Ahmed, Ahmed A Ismail, Atif H Alsahari, Abdulmajeed A Alotay, Tarek S Momenah
Pediatric Cardiology Department, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia. · Cardiac Surgery Department, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
Key points
From the paper's conclusion- This single-center experience from the Middle East demonstrates that Harmony TPV implantation is a feasible and safe procedure with excellent early clinical and echocardiographic outcomes. These findings are consistent with previously published international series and support the adoption of this technology in specialized centers for managing severe PR in patients with complex RVOT anatomy.
Abstract
BACKGROUND: Significant pulmonary regurgitation (PR) is a common late complication after repair of right ventricular outflow tract (RVOT) lesions, potentially leading to right ventricular failure. The Harmony transcatheter pulmonary valve (TPV) was developed for large, native, or patched RVOTs. Although multicenter studies have shown favorable results, regional single-center data, particularly from the Middle East, are scarce. This study reports our initial single-center experience with Harmony TPV implantation, focusing on procedural success, safety, and 1-year outcomes. METHODS: We conducted a retrospective analysis of 10 consecutive patients who underwent Harmony TPV implantation at our institution. Data were collected on baseline characteristics, procedural details, and outcomes. Procedural success, complications, and hemodynamic performance were assessed. RESULTS: The median age of our population was 15.5 years, and 70% of patients were male. The most common underlying diagnosis was post-tetralogy of Fallot repair (50%). All patients had severe PR at baseline. Technical success was achieved in all patients. There was no mortality. Minor periprocedural complications occurred in 4 patients, including minor femoral vein avulsion, fever, ecchymosis, and frequent premature ventricular contractions, all managed conservatively. At 1-year follow-up, freedom from death, moderate/severe PR, mean RVOT gradient >40 mm Hg, or reintervention was 100%. No endocarditis, valve thrombosis, or stent fracture was observed. CONCLUSIONS: This single-center experience from the Middle East demonstrates that Harmony TPV implantation is a feasible and safe procedure with excellent early clinical and echocardiographic outcomes. These findings are consistent with previously published international series and support the adoption of this technology in specialized centers for managing severe PR in patients with complex RVOT anatomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multicenter experience of hybrid transcatheter pulmonary valve implantation in patients with a large right ventricular outflow tract.Frontiers in cardiovascular medicine · 2026
- Harmony™ Valve Implantation in the Right Pulmonary Artery in a Patient with Repaired Tetralogy of Fallot and Left Pulmonary Artery Occlusion: A Case Report.Journal of cardiology cases · 2026
- Transcatheter Pulmonary Valve Implantation With the Alterra Adaptive Prestent and SAPIEN 3 Transcatheter Heart Valve: 3-Year Pooled Outcomes of the ALTERRA TrialsCirculation Cardiovascular Interventions · 2026
- Self-Expandable Harmony Valve Implantation in Supravalvular Pulmonary Position After Senning Procedure: A Case Report.Pediatric cardiology · 2026
- Transcatheter Pulmonary Valve Implantation After Native Right Ventricular Outflow Tract Reconstruction: State-of-the-Art Review.Reviews in cardiovascular medicine · 2026
- Melody, Harmony, and Discord: A Complication During Pulmonic Valve Intervention in a Patient With Tetralogy of Fallot.Cureus · 2026