Self-Expandable Harmony Valve Implantation in Supravalvular Pulmonary Position After Senning Procedure: A Case Report.
Andrei Crauciuc, Stanimir Georgiev, Andreas Eicken, Peter Ewert, Katarzyna Gendera
Center for Advanced Medical and Pharmaceutical Research, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, Romania. andrei.crauciuc@umfst.ro. · Department of Congenital Heart Disease and Paediatric Cardiology, German Heart Center Munich, TUM University Hospital, Munich, Germany.
Key points
From the paper's conclusion- This case demonstrates that Harmony valve implantation in a supravalvular pulmonary position is feasible in patients with Transposition of the Great Arteries following atrial switch repair, despite complex anatomy and suboptimal distal oversizing, when the procedure is guided by comprehensive multimodality imaging and adapted implantation strategies.
Abstract
Transcatheter pulmonary valve implantation has emerged as a minimally invasive therapeutic strategy for the management of right ventricular outflow tract dysfunction, particularly in patients considered unsuitable for repeat surgical intervention. Implantation of the self-expandable Harmony valve represents a therapeutic option for patients with large right ventricular outflow tracts that are unsuitable for balloon-expandable devices. However, significant anatomical variability, particularly in patients following the atrial switch procedure, poses procedural challenges and underscores the importance of meticulous pre-procedural planning. A 44-year-old male with Transposition of the Great Arteries underwent a Senning-Brom procedure in infancy, followed by surgical correction of a baffle leak and pulmonary valve reconstruction at the age of 22. Over time, he developed progressive severe pulmonary regurgitation, confirmed by serial MRI, showing worsening regurgitant fraction (44%) and significant left ventricular (subpulmonic) dilation. The pre-procedural CT screening report for the Harmony valve (TPV25) revealed complex LVOT anatomy, with adequate proximal anchoring but suboptimal distal oversizing. Despite complex anatomy and suboptimal distal oversizing, the procedure was undertaken based on the anatomical dimensions of the main pulmonary artery, favorable proximal anatomy, and a safe distance from the coronary arteries. The procedure was performed via femoral access, and the valve was advanced into the pulmonary artery and deployed in a controlled, stepwise manner at a high level of the bifurcation. Final angiography confirmed stable positioning, optimal anchoring, and complete resolution of pulmonary regurgitation, with preserved coronary flow and no evidence of compression, indicating a successful outcome. This case demonstrates that Harmony valve implantation in a supravalvular pulmonary position is feasible in patients with Transposition of the Great Arteries following atrial switch repair, despite complex anatomy and suboptimal distal oversizing, when the procedure is guided by comprehensive multimodality imaging and adapted implantation strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transcatheter Pulmonary Valve Implantation After Native Right Ventricular Outflow Tract Reconstruction: State-of-the-Art Review.Reviews in cardiovascular medicine · 2026
- Harmony™ Valve Implantation in the Right Pulmonary Artery in a Patient with Repaired Tetralogy of Fallot and Left Pulmonary Artery Occlusion: A Case Report.Journal of cardiology cases · 2026
- Multicenter experience of hybrid transcatheter pulmonary valve implantation in patients with a large right ventricular outflow tract.Frontiers in cardiovascular medicine · 2026
- Early Outcomes of Harmony Transcatheter Pulmonary Valve Implantation in the Middle East: A Single-Center Experience From Saudi Arabia.CJC pediatric and congenital heart disease · 2026
- Case Example and Bench Testing of Hydrodynamic Performance and Migration Stability of Various Valve-in-Valve Configurations within a Large-Housing Self-Expanding Pulmonary Valve.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- First-in-Human Valve-in-Valve Implantation of a Self-Expanding Pulmonary Valve Within a Dysfunctional Balloon-Expandable Pulmonary Valve.JACC. Case reports · 2026