Novel Transcatheter Device Use in Patent Ductus Arteriosus Closure in an 800-g Infant.
Michael N Gritti, Nicholas Fitzgerald
Division of Cardiology, Heart Institute, Children's Hospital Colorado, University of Colorado Denver, Aurora, Colorado, USA; Division of Cardiology, Department of Paediatrics, Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada. · Division of Cardiology, Department of Paediatrics, Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada. Electronic address: nicholas.fitzgerald@sickkids.ca.
Key points
From the paper's conclusion- We report a successful Azur implantation in a 21-day-old infant weighing 830 g at the time of the procedure, representing the lowest procedural weight reported for this device.
Abstract
BACKGROUND: Outcomes of transcatheter patent ductus arteriosus (PDA) occlusion in premature infants have improved with low-profile devices. The Azur Vascular Plug is a soft, uncovered, microcatheter-deliverable device described as a novel option for PDA closure in premature infants. FIRST-IN-HUMAN/EARLY REPORTS: We report a successful Azur implantation in a 21-day-old infant weighing 830 g at the time of the procedure, representing the lowest procedural weight reported for this device. DISCUSSION: The ductal anatomy was unsuitable for a 3-2 mm Piccolo device because of aortic obstruction from extrinsic compression. After Azur deployment, there was no residual shunt or obstruction to adjacent vessels. NOVELTY: This is the smallest patient reported to undergo Azur device closure of a premature PDA, extending its application for this off-label indication. TAKE-HOME MESSAGE: The Azur device may provide an effective, low-profile option for PDA closure in extremely premature infants with challenging ductal anatomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of outcomes after transcatheter patent ductus arteriosus closure in infants weighing ≤ 1.5 kg and > 1.5-4 kg.European journal of pediatrics · 2026
- Transcatheter Closure of Residual Shunt Using the Coil-in-Plug Method After Amplatzer Vascular Plug Implantation for Tubular Patent Ductus Arteriosus in Infants: Two Case Reports.Pediatric cardiology · 2026
- Off-Pump Retrieval of Patent Ductus Arteriosus Closure Device Causing Partial Aortic Obstruction.JACC. Case reports · 2026
- Suspected Infective Endocarditis in a Premature Neonate After Patent Ductus Arteriosus Occluder Placement: A Case Report.Case reports in pediatrics · 2026
- Balloon-assisted TorqVue TM delivery catheter advancement for residual patent ductus arteriosus closure in a postsurgical infant with Edwards syndrome.Cardiology in the young · 2026
- Transcatheter Patent Ductus Arteriosus Closure in Extremely Premature Infants: Transition to the Bedside.JACC. Cardiovascular interventions · 2026