Comparison of outcomes after transcatheter patent ductus arteriosus closure in infants weighing ≤ 1.5 kg and > 1.5-4 kg.
Katia Librandi, Carles Bautista-Rodriguez, Gianfranco Butera, Giuseppe Annoni, Paul Padovani, Sandrine Foldvari, Alban-Elouen Baruteau, Alain Fraisse
Pediatric Cardiology, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK. · Cardiology, Cardiac Surgery and Heart Lung Transplantation, Bambino Gesù Hospital and Research Institute, IRCCS, Rome, Italy.
Key points
From the paper's conclusion- Transcatheter PDA closure is safe and effective in infants ≤ 4 kg, but the > 1.5-4 kg group has a higher risk of major adverse events, particularly device embolization. Better patient selection and dedicated devices may improve safety.
Abstract
UNLABELLED: Transcatheter closure of patent ductus arteriosus (PDA) with the Amplatzer Piccolo Occluder is safe and effective in infants ≤ 2 kg. In larger infants, off-label devices are often required, but outcome data are limited. We evaluated outcomes in infants ≤ 4 kg, comparing the ≤ 1.5 and > 1.5-4 kg groups. This retrospective, international, multicenter study included 358 infants who underwent transcatheter PDA closure at 5 tertiary centers between 2016 and 2024: 191 weighed ≤ 1.5 kg (group 1) and 167 > 1.5-4 kg (group 2). Median age was 39 days (interquartile range 25-61) and median weight was 1.48 (1.1-2.2) kg; 93.6% were preterm. Procedural success was higher in group 1 (98.4% vs 94.0%; p = 0.044). Major adverse events were more frequent in group 2 (9.6% vs 3.1%; p = 0.0144; odds ratio = 3.27; 95% confidence interval, 1.25-8.55). Device embolization occurred only in group 2 (5.4% vs 0%; p < 0.001; odds ratio = 22.96; 95% confidence interval, 1.33-397.51). The Amplatzer Piccolo Occluder was used in 97.3% of group 1 vs 69.5% of group 2. CONCLUSION: Transcatheter PDA closure is safe and effective in infants ≤ 4 kg, but the > 1.5-4 kg group has a higher risk of major adverse events, particularly device embolization. Better patient selection and dedicated devices may improve safety. WHAT IS KNOWN: • Transcatheter PDA closure with the Amplatzer Piccolo Occluder is safe and effective in very small infants. • In larger infants, alternative devices are often used off-label, but evidence on procedural outcomes remains limited. WHAT IS NEW: • Infants weighing >1.5-4 kg had lower procedural success and more major adverse events than those weighing ≤1.5 kg. • Device embolization occurred exclusively in the >1.5-4 kg group, supporting careful anatomical assessment and the development of dedicated devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Novel Transcatheter Device Use in Patent Ductus Arteriosus Closure in an 800-g Infant.JACC. Case reports · 2026
- The Incidence, Severity and Clinical Consequence of Left Pulmonary Artery Stenosis After PDA Device Closure in Premature Infants Less Than 2 Kilograms.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Making sense of the evidence: designing randomised controlled trials for preterm infants with high-shunt volume patent ductus arteriosusArchives of Disease in Childhood Fetal & Neonatal · 2026
- Transcatheter Patent Ductus Arteriosus Closure in Extremely Premature Infants: Transition to the Bedside.JACC. Cardiovascular interventions · 2026
- Efficacy and safety of oral paracetamol versus intravenous paracetamol in preterm infants with patent ductus arteriosus: a randomised controlled trial.Singapore medical journal · 2026
- Transcatheter Closure of Residual Shunt Using the Coil-in-Plug Method After Amplatzer Vascular Plug Implantation for Tubular Patent Ductus Arteriosus in Infants: Two Case Reports.Pediatric cardiology · 2026