Additional FiberTape-Cerclage® augmentation or "Bumper-plate" osteosynthesis for symphyseal arthrodesis - A biomechanical study.
Tobias Fritz, Jasmin Keßler, Marcel Orth, Tim Pohlemann, Antonius Pizanis, Swen Norrick, Emmanouil Lioadiks, David Engel
Saarland University, Faculty of Medicine, Deparment for Trauma, Hand and Reconstructive Surgery, Kirrbergerstr. 100, 66421, Homburg/Saar, Germany; Saarland University Medical Center, Department for Trauma, Hand and Reconstructive Surgery, Kirrbergerstr. 100, 66421, Homburg/Saar, Germany. Electronic address: tobias.fritz@uks.eu. · Saarland University, Faculty of Medicine, Deparment for Trauma, Hand and Reconstructive Surgery, Kirrbergerstr. 100, 66421, Homburg/Saar, Germany.
Key points
From the paper's conclusion- Fiber-Tape cerclage augmentation significantly enhances distraction resistance and preserves contact area compared to dual plating. Furthermore, this technique will potentially allow improved radiological visualization of the area of interest in the pubic symphysis after arthrodesis to analyze bone healing and osteointegration.
Abstract
BACKGROUND: Chronic anterior pelvic instability may require symphyseal arthrodesis when conservative treatment and isolated plating fail. Therefore, dual plating has been clinically used to improve stability. As a novel augmentation FiberTape® cerclage may provide and alternative stabilization method with comparable mechanical stability, providing radiolucency for improved analysis of bone healing. Therefore, we conducted a biomechanical study to compare the effects of dual plating to a plate/ FiberTape® cerclage construct. METHODS: Twenty-four synthetic pelvic models (n = 8 per group) were stabilized using symphyseal plating, dual plating, or plate-cerclage constructs. Cyclic axial loading (50-400 N) was applied in a unilateral stance and bilateral-leg stance biomechanical model. RESULTS: The plate-cerclage resulted in significantly higher compression force (131.5 ± 31.7 N) compared to plate-only fixation (88.2 ± 20.9 N; p = 0.019), corresponding to a 49% increase. Dual plating reduced contact area (p ≤ 0.049). No significant differences were observed in one-leg stance. CONCLUSION: Fiber-Tape cerclage augmentation significantly enhances distraction resistance and preserves contact area compared to dual plating. Furthermore, this technique will potentially allow improved radiological visualization of the area of interest in the pubic symphysis after arthrodesis to analyze bone healing and osteointegration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fixation of Zone 2 Sacral Fractures Utilizing a Novel Compressive Bolt - A Biomechanical Comparison.Journal of orthopaedic trauma · 2026
- Biomechanical Comparison of Three Fixation Constructs for Tile Type C1.2 Pelvic Ring Fractures: A Finite Element AnalysisLife · 2026
- Biomechanical evaluation of cerclage fixation constructs in a 3-dimensionally printed canine tibial long-oblique fracture model.American journal of veterinary research · 2026
- Comparison of novel anterior fixation method, W-plate, versus superior parasymphyseal plating in anterior posterior compression type III pelvic ring injuries: a biomechanical study.Journal of orthopaedic trauma · 2026
- Biomechanical comparison of laminoplasty and in-site regrafting versus laminectomy with pedicle screw fixation for localized thoracic pathological ossification of the ligamentum flavum: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Allograft Strut Fixation to Humeral Bone: A Biomechanical Comparison of Suture-Tape Cerclage, Wire Cerclage, and Screws.Journal of shoulder and elbow surgery · 2026