Virtual low-keV CT imaging enhances tumor contrast and provides favorable diagnostic assessability in oral cavity carcinoma: Comparison with MRI and polyenergetic CT.
Andreas Steven Kunz, Henner Huflage, Stefan Hartmann, Urs Mueller-Richter, Sina Hoehlein, Christian Kestler, Thorsten Alexander Bley, Jan-Peter Grunz,
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany. Electronic address: Kunz_A@ukw.de. · Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
Key points
From the paper's conclusion- Low-energy VMI improves objective tumor attenuation and contrast-to-noise ratio compared with conventional PEI. Subjective diagnostic assessability ratings were favorable for both VMI and MRI, whereas metal artifacts were more pronounced in VMI and motion artifacts were more common in MRI. Although no pairwise differences in tumor area remained statistically significant after correction for multiple comparisons, these findings do not establish equivalence in tumor delineation or diagnostic performance compared with MRI.
Abstract
BACKGROUND: Low-energy virtual monoenergetic imaging (VMI) improves tumor contrast in contrast-enhanced CT. Whether it can provide tumor delineation comparable to MRI in oral cavity carcinoma remains unclear. OBJECTIVE: To compare objective and subjective image quality, artifact burden, and two-dimensional tumor area measurements between 40-keV VMI, conventional polyenergetic CT images (PEI), and contrast-enhanced MRI in patients with oral cavity carcinoma. METHODS: Seventy-two patients (33 women; mean age, 70.2 ± 11.9 years) with newly diagnosed oral cavity carcinoma underwent contrast-enhanced MRI and dual-source dual-energy CT. Forty-keV VMI, PEI, and contrast-enhanced T1-weighted MRI with Dixon-based fat saturation were compared. Objective image quality was assessed using ROI-based measurements of tumor attenuation and contrast-to-noise ratio (CNR). Three readers independently noted 2D tumor dimensions and rated metal and motion artifacts as well as diagnostic assessability. RESULTS: Tumor attenuation was significantly higher in VMI than in PEI (median, 274.3 [IQR 236.7-316.5] vs 136.3 [114.9-154.5] HU), as was CNR (10.4 [6.6-15.8] vs 7.6 [3.3-11.9]; both p < 0.001). In five patients, severe metal artifacts rendered CT non-diagnostic. Among the 67 patients with evaluable examinations across all three modalities, median tumor area was 285.0 mm2 (IQR 195.0-705.0) in VMI, 320.0 mm2 (IQR 206.0-701.0) in PEI, and 312.0 mm2 (IQR 210.0-692.0) in MRI. The overall comparison was significant (p = 0.021), but no pairwise differences remained significant after correction for multiple comparisons. Metal artifacts were more pronounced in VMI than MRI (p < 0.001), whereas motion artifacts were more common in MRI (p < 0.001). Overall diagnostic assessability was higher for VMI and MRI than for PEI (both p ≤ 0.009). Inter-reader agreement was moderate to excellent (ICC ≥ 0.72). CONCLUSION: Low-energy VMI improves objective tumor attenuation and contrast-to-noise ratio compared with conventional PEI. Subjective diagnostic assessability ratings were favorable for both VMI and MRI, whereas metal artifacts were more pronounced in VMI and motion artifacts were more common in MRI. Although no pairwise differences in tumor area remained statistically significant after correction for multiple comparisons, these findings do not establish equivalence in tumor delineation or diagnostic performance compared with MRI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Photon-Counting CT With Low-keV Virtual Monoenergetic Images for Detecting Muscle Invasion in Bladder Cancer: A Prospective Study.AJR. American journal of roentgenology · 2026
- Photon-counting detector CT with virtual monoenergetic imaging and iterative metal artifact reduction for spinal fusion implants: optimal keV and combined benefits.European journal of radiology · 2026
- Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.Diagnostics (Basel, Switzerland) · 2026
- Adnexal cyst pseudoenhancement and optimal attenuation change threshold determination at low keV reconstructions at photon counting CT.Abdominal radiology (New York) · 2026
- Image quality assessment of 40-keV virtual monoenergetic reconstruction in low-contrast lower-extremity spectral CT angiography.Radiography (London, England : 1995) · 2026
- Feasibility of low concentration iodinated contrast medium in portal venous abdominal imaging: performance of photon-counting CT virtual monoenergetic imaging compared to conventional EID-CT.European journal of radiology · 2026