Abdominal radiology (New York)

Adnexal cyst pseudoenhancement and optimal attenuation change threshold determination at low keV reconstructions at photon counting CT.

Daniel Parrott, Danielle Rigau, Bhavik Bansal, Barun Bagga, Bari Dane

New York University, New York, United States. daniel.parrott@nyulangone.org. · New York University, New York, United States.

Key points

From the paper's conclusion
  • "Pseudoenhancement" of adnexal lesions occurs with increasing frequency with decreasing keV below 60 keV, but there was no "pseudoenhancement" at 67 or 70 keV. Energy-specific attenuation thresholds improve adnexal lesion characterization.

Abstract

PURPOSE: To evaluate "pseudoenhancement" in adnexal lesions on low kiloelectron volt (keV) virtual monoenergetic images (VMI) at photon-counting CT (PCCT) and to establish optimal attenuation change thresholds for distinguishing enhancing from nonenhancing lesions at each VMI. METHODS: Adult women who underwent contrast-enhanced abdominopelvic PCCT and pelvic MRI or ultrasound (US) within 180 days were identified via retrospective PACS search. Adnexal lesions were classified as enhancing or nonenhancing using MRI or US as the reference standard. Quantitative attenuation measurements were obtained using regions-of-interest at VMI levels (70, 67, 60, 55, 50, 45, and 40 keV). "Pseudoenhancement" was defined as ≥ 20 Hounsfield units (HU) increase between the VMI and virtual unenhanced (VUE) images. The diagnostic performance of a 20HU change to define enhancement at each VMI level was assessed. Receiver operating characteristic (ROC) curve analysis was used to determine optimal thresholds by maximizing the Youden index. Inter-reader agreement was evaluated with intraclass correlation coefficients. RESULTS: Forty-five women (median [IQR] age 46 years [37, 54] ) with 30 nonenhancing and 15 enhancing adnexal lesions were included. No "pseudoenhancement" was observed at 70 or 67 keV; however, "pseudoenhancement" was observed in 3.3% of patients at 60 keV, increasing to 26.7% at 40 keV. Using a 20 HU change to indicate enhancement had 47% sensitivity with 100% specificity at 70 keV and 93% sensitivity with 73% specificity at 40 keV. Optimal attenuation thresholds increased with decreasing energy, from 10.0 HU at 70 keV to 36.3 HU at 40 keV. Notably, at 60 keV, the threshold was 19.1HU. Inter-reader agreement was near perfect (ICC = 0.858, 95%CI = 0.756-0.920). CONCLUSION: "Pseudoenhancement" of adnexal lesions occurs with increasing frequency with decreasing keV below 60 keV, but there was no "pseudoenhancement" at 67 or 70 keV. Energy-specific attenuation thresholds improve adnexal lesion characterization.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers