The residual stress induced differences of aortic arch morphology between in vivo and in vitro states.
Ya-Qing Yang, Yu-Heng Yang, Robert Guidoin, Zeng-Sheng Chen, Mei-Ce Tian, Xiao-Yan Deng, Yu-Bo Fan, Hong-Yan Kang,
Key Laboratory for Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Centre for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China. · Department of Surgery, Universite Laval and Centre de Recherche du CHU de Quebec, Québec, QC G1A 0A6, Canada.
Key points
From the paper's conclusion- This research investigated the relevance between residual stress and aortic bending configuration as well as local stress distribution, which provided additional understanding of its theory.
Abstract
BACKGROUND: Despite a long history of more than 30 years, the residual stress in aortic arch has not been attached sufficient attention in the clinical treatment of cardiovascular diseases and the design of medical devices in the era of endovascular intervention. METHODS: This study reconstructed in vivo and in vitro aortic arch models of six rats. Their geometric parameters were compared to visualize the effects of residual stress on maintaining bending configuration. Then the stress distributions within vessels were numerically analyzed. FINDINGS: The experimental results showed that average arch width of in vitro models (6.22 mm ± 0.58 mm) was 27.08% smaller (p < 0.001) than that of in vivo models (8.53 mm ± 0.19 mm) due to the residual stress release. While the mean arch curvature of in vitro models (0.48 ± 0.08) was 120.36% greater (p < 0.001) than that of in vivo models (0.22 ± 0.02). The finite element analyses showed a more even intramural stress distribution under blood pressure in model with residual stress considered. INTERPRETATION: This research investigated the relevance between residual stress and aortic bending configuration as well as local stress distribution, which provided additional understanding of its theory.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A reduced glycosaminoglycan-linked residual-strain model captures regional opening angle changes after depletion in the porcine thoracic aortabioRxiv · 2026
- Regional mechanical and microstructural variations in ascending thoracic aortic aneurysms influenced by tricuspid and bicuspid aortic valvesActa Biomaterialia · 2026
- A Fluid–Structure Interaction Computational Study of Residual Aortic Dissection to Investigate the Influence of Mechanical Behaviour of Wall and Flap on FlowsInternational Journal for Numerical Methods in Biomedical Engineering · 2025
- Finite Element Investigation of the Influence of Strut Diameter on the Mechanical Performance of Balloon-Expandable Biodegradable PLA/PDO Coronary Stents.Polymers · 2026
- Coronary artery distensibility after stent implantation – an in vitro mock artery study based on optical coherence tomographyCurrent Directions in Biomedical Engineering · 2026
- Impact of Bridging Stent Flaring Angle on Hemodynamic Performance-In Vitro Analysis.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026