Coronary artery distensibility after stent implantation – an in vitro mock artery study based on optical coherence tomography
Christoph Brandt-Wunderlich, Wolfram Schmidt, Michael Stiehm, Klaus-Peter Schmitz, Stefan Siewert
Key points
From the paper's conclusion- Within the current study we used silicone mock arteries to investigate the influence on stent implantation on coronary artery distensibility using a custom-made in vitro test setup based on a diameter measurement via optical coherence tomography (OCT).
Abstract
The radial distensibility of the coronary arteries plays a critical role in maintaining physiological blood flow and wall shear stress distribution. Atherosclerosis as well as stent implantation alters the elastic properties, leading to a localized stiffening of the arterial segment. Within the current study we used silicone mock arteries to investigate the influence on stent implantation on coronary artery distensibility using a custom-made in vitro test setup based on a diameter measurement via optical coherence tomography (OCT). Therefore, pressure dependent measurements of the inner diameter of the mock vessel were performed in original state and after fixing a stent outside the mock artery to mimic ingrowth of the stent. Test results show, that the mock artery distensibility reduces down to 16 % with surrounding stent. The presented data provides essential input parameters for radial fatigue testing of stents.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Realistic anatomical model reconstruction and high-fidelity flow computation in stented coronary arteries for the analysis of in-stent thrombosis.Frontiers in cardiovascular medicine · 2026
- Optical coherence tomography-guided orbital atherectomy for calcified coronary lesions: rationale and design of the CROWN studyNetherlands Heart Journal · 2026
- Experimental comparisons of optical coherence tomography-based versus angiography-based time-averaged wall shear stress estimationsThe International Journal of Cardiovascular Imaging · 2026
- DiffStent: Surrogate Adjoint Differentiation for Stent Deployment in Anisotropic ArteriesarXiv · 2026
- Computational hemodynamic analysis of idealized coronary arteries with cylindrical and conical stentsComputer Methods and Programs in Biomedicine · 2026
- Finite Element Investigation of the Influence of Strut Diameter on the Mechanical Performance of Balloon-Expandable Biodegradable PLA/PDO Coronary Stents.Polymers · 2026