Development and clinical evaluation of an automatic verification system for Oncentra brachytherapy treatment planning.
Jinxin Peng, Jianting Liu, Yongqiang Wang, Ruisong Guo, Zhulin Dong, Xiaofen Xing, Xuegang Chu
Department of Radiation Oncology, Shanxi Province Cancer Hospital, Taiyuan, China; Shanxi Hospital Affiliated to Cancer Hospital, Chinese Academy of Medical Sciences, Taiyuan, China; Department of Radiation Oncology, Cancer Hospital Affiliated to Shanxi Medical University, Taiyuan, China. · Department of Radiation Oncology, Shanxi Province Cancer Hospital, Taiyuan, China; Shanxi Hospital Affiliated to Cancer Hospital, Chinese Academy of Medical Sciences, Taiyuan, China; Department of Radiation Oncology, Cancer Hospital Affiliated to Shanxi Medical University, Taiyuan, China. Electronic address: chuxuegang@126.com.
Key points
From the paper's conclusion- The implemented automated verification system is proven to be reliable and practical for clinical use. It enhances the efficiency of intracavitary and hybrid interstitial HDR brachytherapy plan quality assurance while effectively mitigating the risks associated with human error.
Abstract
PURPOSE: Current manual workflows for verification of high-dose-rate (HDR) intracavitary and hybrid interstitial brachytherapy are labor-intensive and susceptible to errors. This study developed a fully automated verification system to evaluate plan integrity, quality, and dosimetric accuracy, with the aim of improving patient safety and clinical workflow efficiency. METHODS AND MATERIALS: Featuring an automated verification pipeline for treatment plan integrity and a quality evaluation module, the system assesses key metrics: patient data, treatment parameters, applicator information, the number of CT slices, and volumetric and dosimetric constraints for all volumes of interest (VOIs). Additionally, an independent dose calculation based on the American Association of Physicists in Medicine Task Group No. 43 (TG-43) formalism is incorporated. RESULTS: A total of 79 cases successfully passed the integrity check, and the remaining six triggered system-generated warnings. Quality assessment confirmed that the majority of plans met all clinical constraints, with only minor clinically acceptable deviations observed in isolated cases. A mean Gamma passing rate of 98.70% (3%/2 mm criterion) was obtained in independent plan dose verification, and a positive correlation with the target volume was observed. CONCLUSIONS: The implemented automated verification system is proven to be reliable and practical for clinical use. It enhances the efficiency of intracavitary and hybrid interstitial HDR brachytherapy plan quality assurance while effectively mitigating the risks associated with human error.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Preliminary feasibility results for implementing a phantom model for external auditing of HDR brachytherapy with an Ir-192 HDR source: an IAEA collaborative project.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Independent Three-dimensional Dose Calculation from Log Files for Breast VMAT: A Measurement-free Quality Assurance Approach.Journal of medical physics · 2026
- Investigation of TG-43 dose calculation algorithm for volumetric HDR Brachytherapy using Monte Carlo simulation in TOPAS.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A Monte Carlo based dose verification tool for an HDR Ir-192 brachytherapy source and its evaluation on extremity malignancies.Journal of applied clinical medical physics · 2026
- Automated verification of source dwell position in lunar ovoid applicators.Journal of applied clinical medical physics · 2026
- Three-dimensional deep learning nomogram for post-plan quality assurance in high-dose-rate prostate brachytherapy.Physics and imaging in radiation oncology · 2026