Preliminary feasibility results for implementing a phantom model for external auditing of HDR brachytherapy with an Ir-192 HDR source: an IAEA collaborative project.
N Briggs, A C F Silva, S P Leite, A Silva, A Bernardino, M H Marechal, C Salata, A X Silva,
Universidade Federal Do Rio de Janeiro/Coordenação Dos Programas de Pós Graduação e Pesquisa de Engenharia da Universidade Federal Do Rio de Janeiro, Cidade Universitária, Rio de Janeiro, 21941-616, Brazil; Universidade Do Estado Do Rio de Janeiro/Laboratório de Ciências Radiológicas, Departamento de Ciências Radiológicas, R. São Francisco Xavier, 524, CEP, Maracanã, Rio de Janeiro, 20550-900, Brazil. Electronic address: natashabriggs.silva@gmail.com. · Universidade Federal Do Rio de Janeiro/Coordenação Dos Programas de Pós Graduação e Pesquisa de Engenharia da Universidade Federal Do Rio de Janeiro, Cidade Universitária, Rio de Janeiro, 21941-616, Brazil.
Key points
From the paper's conclusion- This work presents the development and validation of a methodology for external auditing in high-dose-rate (HDR) brachytherapy using an Ir-192 source, conducted within the scope of a research project coordinated by the International Atomic Energy Agency (IAEA), with the participation of nine countries.
Abstract
Accuracy in dose delivery in brachytherapy treatments is a critical component for clinical success and patient safety, requiring a rigorous quality assurance system. The implementation of external dosimetric audits plays a fundamental role in verifying the planned and delivered doses, allowing the identification of discrepancies that could compromise tumor control or increase toxicity in healthy tissues, as well as ensuring compliance with national and international recommendations and standards. This work presents the development and validation of a methodology for external auditing in high-dose-rate (HDR) brachytherapy using an Ir-192 source, conducted within the scope of a research project coordinated by the International Atomic Energy Agency (IAEA), with the participation of nine countries. A positioning phantom, manufactured through 3D printing, was designed to accommodate various models of intracavitary applicators, allowing adaptable and reproducible assembly conditions for dosimetric evaluation. Optically Stimulated Luminescence (OSL) dosimeters (nanoDot model) were used for point dose measurements around the applicator, in configurations previously standardized based on the results obtained from earlier tests leading to the final prototype. The coordinates of these points were registered in the Treatment Planning System (TPS) and used as a reference for experimental comparison, respecting distances and depths equivalent to those defined in the planning. The applied methodology allowed the comparison between the experimental data obtained with NanoDot OSL dosimeters and the doses calculated by the TPS. The dosimeters were positioned in a cross-shaped configuration around the applicator, maintaining a distance of 2 cm from the ring and 2 cm from the probe (tandem), ensuring a standardized and reproducible geometric arrangement. The project was funded by project E24023, International Atomic Energy Agency (IAEA), Contract number 24544.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR BrachytherapyarXiv · 2026
- Development and clinical evaluation of an automatic verification system for Oncentra brachytherapy treatment planning.Brachytherapy · 2026
- Development of a low-cost 3D-printed phantom for end-to-end testing of model-based dose calculation algorithms (MBDCAs) in high-dose-rate (HDR) brachytherapy.Journal of applied clinical medical physics · 2026
- Validation of a 3D-printed anthropomorphic eye phantom for quality assurance in external beam radiotherapy using TLD and radiochromic film.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Independent verification of vendor‐issued dosimetric data for¹⁰⁶ Ru brachytherapy using diode detectors with traceability to external beam standards for absorbed dose to waterMedical Physics · 2026
- Investigation of TG-43 dose calculation algorithm for volumetric HDR Brachytherapy using Monte Carlo simulation in TOPAS.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026