Three-dimensional deep learning nomogram for post-plan quality assurance in high-dose-rate prostate brachytherapy.
Joel Beaudry, Tonghe Wang, Shirin A Enger, Antonio L Damato
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA. · Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec, Canada.
Key points
From the paper's conclusion- A deep learning-based nomogram predicted an institution-specific 100% isodose volume with low coverage error and high spatial agreement. This geometry aware post-plan QA tool can complement equation-based nomograms by directly evaluating the spatial treated volume.
Abstract
PURPOSE: Classical nomograms for high-dose-rate (HDR) prostate brachytherapy quality assurance (QA) evaluate agreement between planned and expected total dwell time but do not directly assess the three-dimensional treated volume. This study's aim was to develop a deep learning-based 3D nomogram to predict institution-specific clinical 100% isodose volumes from anatomy and dwell positions for post-plan QA. METHODS: A total of 2394 single-fraction 15 Gy HDR prostate brachytherapy plans were included. Input label maps encoded the 3D prostate, urethra, rectum, and dwell positions. The prediction target was the clinical 100% isodose volume. A five-fold cross-validation strategy was used for model development, with 2155 plans used for training and validation and 239 plans held out for testing. A 3D U-Net was trained using combined Dice and binary cross-entropy loss. Agreement was evaluated using prostate V100%, 100% isodose volume, Dice similarity coefficient, and average symmetric surface distance (ASSD). Validation-derived thresholds were used for outlier screening and targeted review. RESULTS: The model predicted prostate V100% with a mean error of 0.73 percentage points. Predicted and clinical 100% isodose volumes showed strong agreement, with R2 = 0.990, slope = 0.99, and intercept = 0.77 cm3. Median Dice similarity coefficient was 0.960, and median ASSD was 0.48 mm. A 95% threshold flagged 6.3% of plans as atypical relative to validation data. CONCLUSIONS: A deep learning-based nomogram predicted an institution-specific 100% isodose volume with low coverage error and high spatial agreement. This geometry aware post-plan QA tool can complement equation-based nomograms by directly evaluating the spatial treated volume.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Simple and Interpretable DVH Prediction Model: Integrating Distance-to-Target Histograms with Longitudinal Spatial Features.The British journal of radiology · 2026
- Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indicesarXiv · 2026
- Independent Three-dimensional Dose Calculation from Log Files for Breast VMAT: A Measurement-free Quality Assurance Approach.Journal of medical physics · 2026
- Machine learning-based prediction of gamma passing rates in VMAT prostate external radiation therapy plans.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- Impact of needle number on dosimetric parameters in high-dose-rate prostate brachytherapy: A single-institution retrospective study.Journal of contemporary brachytherapy · 2026
- Development and clinical evaluation of an automatic verification system for Oncentra brachytherapy treatment planning.Brachytherapy · 2026