Dual interfacial engineering of Cas12a trans-cleavage and luminophore stability for robust electrochemiluminescence biosensing of tetrodotoxin.
Chao Yan, Ruolan Liu, Jingyi Xu, Jie Zhang, Jiajia Guo, Bangben Yao, Qingxi Wu, Baowei Zhang,
School of Life Science and Medical Engineering, Anhui University, Hefei, 230601, China. Electronic address: yanchao19930215@foxmail.com. · School of Life Science and Medical Engineering, Anhui University, Hefei, 230601, China.
Key points
From the paper's conclusion- Herein, we report a dual interfacial engineering strategy that integrates freeze-thaw treated phosphorothioate modified ssDNA (FT-PS-ssDNA) probes with ruthenium-based metal covalent organic frameworks (Ru-MCOFs) to construct a robust CRISPR/Cas12a-based ECL biosensor.
Abstract
CRISPR/Cas12a-based electrochemiluminescence (ECL) biosensors are promising for trace detection of marine toxins, yet their practical application is often limited by inefficient and poorly reproducible interfacial trans-cleavage and unstable ECL signals. Herein, we report a dual interfacial engineering strategy that integrates freeze-thaw treated phosphorothioate modified ssDNA (FT-PS-ssDNA) probes with ruthenium-based metal covalent organic frameworks (Ru-MCOFs) to construct a robust CRISPR/Cas12a-based ECL biosensor. The FT-PS-ssDNA probes promoted an ordered probe monolayer with a spatially defined Cas12a accessible cleavage region, enabling efficient and reproducible trans-cleavage, while the Ru-MCOFs provided a stable matrix for ECL luminophores, improving signal stability. Under optimized conditions, the biosensor enabled quantitative detection of tetrodotoxin (TTX) from 10 pg/mL to 100 ng/mL, with a detection limit of 2.36 pg/mL. The biosensor showed improved signal reproducibility compared with a conventional CRISPR/Cas12a-based ECL design, together with high specificity toward TTX, satisfactory recoveries in spiked water, serum, and seafood samples, and good agreement with UPLC-MS analysis. Although the dual interfacial strategy improves signal stability and reproducibility, practical deployment still requires further simplification of the multistep assay and evaluation under variable field conditions. Future integration with miniaturized electrodes, simplified sample preparation, and portable ECL devices could facilitate rapid on-site sensing for food safety and environmental monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ytterbium Metal-Organic Framework With DNA Hydrogel Switching for ElectroChemiluminescence Biosensing.Small (Weinheim an der Bergstrasse, Germany) · 2026
- PCR-amplified blaKPC-2-triggered Cas12a activation coupled with DNA cube-confined Fc reporter cleavage on a Ti3C2/CsPbBr3@PDA@Au/GCE dual-mode ECL/SERS interface.Analytical methods : advancing methods and applications · 2026
- Incorporating CRISPR Techniques with Electrochemical Sensors: From Signal-Off to Signal-On Assays.ACS sensors · 2026
- Highly Sensitive Electrochemical Biosensing Strategy Based on Multiple CRISPR/Cas12a Trans-Cleavage Units.Analytical chemistry · 2026
- A dual-mode ECL/SERS biosensor based on protein-regulated CRISPR/Cas12a activation for NF-κB p50 detection and inhibitor screening.Mikrochimica acta · 2026
- An aggregation-induced electrochemiluminescence sensor for ochratoxin A detection integrating CRISPR-Cas12a and tetrahedral DNA nanostructures.The Analyst · 2026