Mikrochimica acta

A dual-mode ECL/SERS biosensor based on protein-regulated CRISPR/Cas12a activation for NF-κB p50 detection and inhibitor screening.

Yanfei Ma, Qingxiao Nong, Shouwen Tao, Haozhen Ren, Jihua Wei, Yuanxun Gong, Yue Huang, Xiao Tang,

Guangxi Key Laboratory of Artificial Intelligence for Genetic Diseases of Long-dwelling Nationalities, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China. · Engineering Research Center of Guangxi Higher Education Institutions for Precise Genetic Testing of Long-Dwelling Nationalities, Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China.

Key points

From the paper's conclusion
  • Overall, this work provides a robust and versatile sensing strategy integrating perovskite-based nanomaterials and dual-mode signal output, offering great potential for highly sensitive biomarker detection and drug screening applications.

Abstract

Sensitive and reliable detection of nuclear factor κB (NF-κB) is of great significance for disease diagnosis and drug screening. We report a dual-mode electrochemiluminescence (ECL)-surface-enhanced Raman scattering (SERS) biosensor based on a CsPbBr₃/PDA/Au/Ti₃C₂ nanocomposite for highly sensitive detection of NF-κB p50. The CsPbBr₃ nanocrystals were integrated with polydopamine (PDA), Au nanoparticles, and Ti₃C₂ MXene to construct a multifunctional nanoplatform with enhanced conductivity, high surface area, and excellent signal transduction capability. Combined with a DNA tetrahedron (DT)-based probe and CRISPR-assisted signal regulation strategy, the biosensor enables dual-signal readout with inverse responses, where the ECL signal decreases while the SERS signal increases upon target recognition. A ratiometric SERS/ECL approach was further employed to improve detection reliability and analytical accuracy. Under optimal conditions, the biosensor exhibited a wide linear detection range from 0.01 fM to 1 pM, with limits of detection as low as 3 aM (ECL) and 6 aM (SERS). The proposed system also demonstrated excellent reproducibility (RSD = 3.85%), operational stability (RSD = 1.68%), and high specificity against various interfering biomolecules. The applicability of the method was further validated by accurate determination of NF-κB p50 in nuclear extract samples, with recoveries ranging from 98.4% to 103.0%. Moreover, the developed biosensor was successfully applied to inhibitor screening. Using (-)-DHMEQ as a model inhibitor, a typical sigmoidal dose-response curve was obtained, and the half-maximal inhibitory concentration (IC₅₀) was determined to be 0.74 nM, demonstrating the capability of the platform for bioactivity evaluation. Overall, this work provides a robust and versatile sensing strategy integrating perovskite-based nanomaterials and dual-mode signal output, offering great potential for highly sensitive biomarker detection and drug screening applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers