Analytical methods : advancing methods and applications

PCR-amplified blaKPC-2-triggered Cas12a activation coupled with DNA cube-confined Fc reporter cleavage on a Ti3C2/CsPbBr3@PDA@Au/GCE dual-mode ECL/SERS interface.

Yijin Chen, Jiangbin Huang, Lusheng Wen, Qigan Zhu, Jinfa Liu, Jiarong Meng, Le Yu

Department of Pathology, The 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, Fujian 363000, China. yule141216@163.com.

Key points

From the paper's conclusion
  • This work provides a self-calibrated dual-mode strategy for antibiotic resistance gene detection, while further validation using bacterial lysates, extracted bacterial genomic DNA, and clinical bacterial isolates is required before diagnostic application. qPCR supported linear amplification over 10-107 copies per µL; endpoint responses remained observable through 108 copies per µL, where quantitat

Abstract

Rapid and reliable detection of antibiotic resistance genes is essential for guiding antimicrobial therapy and controlling the spread of carbapenem-resistant pathogens. Herein, we developed a PCR amplicon-activated CRISPR/Cas12a-regulated dual-mode electrochemiluminescence/surface-enhanced Raman scattering biosensor for sensitive detection of the blaKPC-2 resistance gene. A specific blaKPC-2 fragment containing the selected TTTG PAM region was amplified by PCR and used as a double-stranded DNA activator for the crRNA/Cas12a complex. After target recognition, activated Cas12a cleaved the Fc-labeled reporter segments integrated into a DNA cube scaffold assembled on the Ti3C2/CsPbBr3@PDA@Au nanocomposite interface. In the initial state, Fc was positioned close to the Ti3C2/CsPbBr3@PDA@Au-modified GCE surface, resulting in ECL quenching and strong SERS emission. Upon Cas12a-mediated cleavage of the exposed ssDNA reporter segments, Fc-containing fragments were released from the interface, leading to ECL recovery and SERS attenuation. Therefore, the target-induced process enabled an anti-correlated ECL-on/SERS-off signal conversion, and the ratiometric value R = IECL/ISERS was used for quantitative analysis. The concentration-dependent response was empirically fitted over 10-107 copies per µL, whereas the 108 copies per µL group exhibited upper-range response compression. Boundary back-calculation indicated that further quantitative validation is required. Blank-response inverse prediction gave a model-dependent response-equivalent concentration of approximately 1.06 copies per µL; Poisson sampling gave a 95% molecular-sampling threshold of approximately 3.0 copies per µL for a 1.0 µL input. Neither descriptor is an experimentally determined detection or quantification limit. The platform also exhibited good selectivity against other resistance genes and non-target bacterial genomic DNA, together with satisfactory repeatability, reproducibility, stability, and acceptable spike-recovery performance in 10% diluted serum as a model biological matrix, providing preliminary evidence of matrix tolerance rather than clinical validation. This work provides a self-calibrated dual-mode strategy for antibiotic resistance gene detection, while further validation using bacterial lysates, extracted bacterial genomic DNA, and clinical bacterial isolates is required before diagnostic application. qPCR supported linear amplification over 10-107 copies per µL; endpoint responses remained observable through 108 copies per µL, where quantitative resolution was reduced.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

PCR-amplified blaKPC-2-triggered Cas12a activation coupled with DNA cube-confined Fc reporter cleavage on a Ti3C2/CsPbBr3@PDA@Au/GCE dual-mode ECL/SERS interface — Science Skim