Annals of vascular surgery

Impact of BeFlared Bridging Stent Graft on Fluoroscopy and Procedure Time for Fenestrated Endovascular Aneurysm Repair.

Sandra Lindskog, Anna Bjällmark, Christian Smedberg, David Lindström

Dept of Radiology, Södersjukhuset, Stockholm, Sweden; Dept of Clinical Diagnostics, School of Health and Welfare, Jönköping University, Jönköping, Sweden. · Dept of Clinical Diagnostics, School of Health and Welfare, Jönköping University, Jönköping, Sweden.

Observational · n=48

Key points

From the paper's conclusion
  • BeFlared BSG use in FEVAR led to reduced fluoroscopy and procedure times, along with lower radiation doses, while both graft types demonstrated excellent short-term outcomes.

Abstract

OBJECTIVE: This study aimed to determine whether BeFlared bridging stent grafts (BSG) reduce fluoroscopy and procedure times during Fenestrated Endovascular Aneurysm Repair (FEVAR) compared to traditional BSGs. Secondary endpoints included radiation doses, contrast agent volumes, and 30-day outcomes. METHODS: A retrospective cohort of patients treated with FEVAR from 2021 to 2026 was analyzed. Patients receiving BeFlared BSG (2025-2026) were compared with those treated with traditional BSGs (2021-2025). Demographics and procedural parameters, including fluoroscopy and procedure times, radiation doses, and contrast volumes, were collected. Technical success and 30-day outcomes, including target vessel instability (TVI), were assessed through clinical visits and computed tomography angiography. RESULTS: A total of 48 patients with 177 target vessels (TVs) were included: 59 TVs treated with BeFlared BSG and 118 with Advanta/BeGraft. The BeFlared group had significantly shorter fluoroscopy time (54 (95% CI: 49-70) minutes vs. 79 (76-91) minutes; p < 0.01) and procedure time (169.5 minutes (153.5-187) vs. 208.5 minutes (196-247) ; p = 0.02). Significant differences were also noted in radiation dose (Air Kerma, 1500 (1191-1906) vs. 2448 (1725-2950) p = 0.01; DAP, 157.8 (131.3-192.8) vs. 260.7 (187.7-374.5) p = 0.04). Contrast volumes were similar (p = 0.5). Technical success was good in both groups (BeFlared 98.3% vs. Advanta/BeGraft 97.4%; p = 0.37); with TVI at 3% in the BeFlared group versus 2% in Advanta/BeGraft (p = 0.59). No stent-related endoleaks were observed. CONCLUSIONS: BeFlared BSG use in FEVAR led to reduced fluoroscopy and procedure times, along with lower radiation doses, while both graft types demonstrated excellent short-term outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers