From the paper's conclusion- The VBX demonstrated high technical success and low complication rate. Target vessel incorporation with branches carried higher rates of complications compared to fenestrations.
Abstract
BACKGROUND: Target vessel outcomes affect fenestrated and branched endovascular aortic repair (f/bEVAR) durability. This systematic review and meta-analysis aimed to assess Viabahn balloon expandable (VBX) covered stent outcomes for bridging in f/bEVAR. METHODS: This systematic review was conducted according to PRISMA (PROSPERO: CRD420251034221). Database search was performed in PubMed, Cochrane Library and Embase. Studies between 2017-2025 reporting on f/bEVAR patients managed with bEVAR using the VBX for target vessel bridging were included. The risk of bias was assessed with ROBINS-I and the quality of evidence with GRADE. Target vessel technical success, instability (TVI), occlusion/stenosis, endoleak and reintervention rate were assessed as primary outcomes. RESULTS: Among 1728 studies, 16 were included (2214 patients, 5440 target vessels; 4406 branches, 993 fenestrations; 2918 bridged using VBX). Eight studies were at serious and eight at moderate risk of bias (ROBINS-I). Quality of evidence was 'very low' for all primary outcomes (GRADE). The median follow-up was 12.1 months (95% CI 9.1-15.1). Target vessel technical success was 98.9% (95% CI 97.3-99.5%; I2=0%), while TVI was 5.4% (95% CI 3.7-7.6%; I2=62%), occlusion/stenosis 3% (95% CI 1.8-4.9%; I2=62%), endoleak Ic/IIIc 2.9% (95% CI 2.2-3.7%; I2=0) and reintervention rate 3.1% (95% CI 1.6-6.1%; I2=54%). Analysis per vessel type revealed higher TVI for renal arteries. Subgroup analysis per incorporation type revealed higher technical success, but worse TVI, occlusion/stenosis and reintervention rate for branches. CONCLUSIONS: The VBX demonstrated high technical success and low complication rate. Target vessel incorporation with branches carried higher rates of complications compared to fenestrations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Midterm outcomes of VBX bridging stent grafts in complex branched endovascular aortic repair.The Journal of cardiovascular surgery · 2026
- Preliminary experience with the low profile VBX as bridging stent-graft in fenestrated and branched endovascular aortic repair.The Journal of cardiovascular surgery · 2026
- Real world one-year outcomes of the GORE® VIABAHN® balloon-expandable endoprosthesis in FEVAR and BEVAR: insights from the EXPAND and EMBRACE registries.The Journal of cardiovascular surgery · 2026
- One-Year Results From the EMBRACE Registry Evaluating the GORE VIABAHN VBX Balloon Expandable Endoprosthesis during BEVAR for Complex Abdominal and Thoracoabdominal Aneurysms.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
- "Flaring the gap": short-term results and outcomes of using BeFlared, a pre-flared covered bridging stent in fenestrated endovascular aortic repair. The Danish experience.The Journal of cardiovascular surgery · 2026
- Long Term Target Vessel Outcomes in Patients Treated with Fenestrated Endovascular Aortic RepairEuropean Journal of Vascular and Endovascular Surgery · 2026