The Journal of cardiovascular surgery

Preliminary experience with the low profile VBX as bridging stent-graft in fenestrated and branched endovascular aortic repair.

Stefania Caputo, Enrico Gallitto, Antonio Cappiello, Silvia Morreale, Andrea Vacirca, Paolo Spath, Rodolfo Pini, Gianluca Faggioli,

Unit of Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy - caputostefania@hotmail.it. · Unit of Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy.

Observational · n=47

Key points

From the paper's conclusion
  • The BX stent-graft appears safe and effective in F/B-EVAR, with satisfying preliminary results. Larger studies with longer follow-up are required to confirm BX durability.

Abstract

BACKGROUND: Fenestrated and branched endovascular repair (F/B-EVAR) for thoracoabdominal (TAAA) and juxta/pararenal (J/P-AAA) aortic aneurysms has shown good mid- and long-term outcomes; however, the bridging stent graft (BSG) choice remains debated. A new low-profile BSG, The GORE® VIABAHN® VBX Balloon Expandable (BX) was introduced in December 2024. The aim was to report the BX preliminary outcomes in F/B-EVAR. METHODS: Consecutive patients treated with at least 1 BX in F/B-EVAR between January and August 2025 were retrospectively analyzed. Early outcomes (30 days/in-hospital) included technical and clinical success, patency, and target vessel instability (TVI). Six-month outcomes included secondary endoleak, patency, and TVI, according to the Society for Vascular Surgery (SVS) reporting standards. RESULTS: A total of 180 target vessels (TVs) in 47 patients were analyzed. Procedures included 17 preloaded-FEVAR, 11 off-the-shelf T-branch, 11 custom-made (CM) BEVAR, and 8 CM-F/B-EVAR. Indications included: 20 TAAA, 19 J/P-AAA, and 8 type IA endoleaks in EVAR. Median aneurysm diameter was 60 mm (53-66). Technical success was achieved in 99.4% (179/180 TVs), with 100% assisted technical success. Clinical success was 89.4% (42/47 patients), all BX-unrelated. Thirty-day TVI was 0.5%, with one renal branch occlusion successfully treated, leading to a secondary patency of 100%. At 6-months, 46 patients completed imaging. One renal fenestration type IC endoleak and one additional renal branch occlusion were observed. Overall primary and secondary patency were 98.9% and 99.4%, respectively. TVI was 1.7%. CONCLUSIONS: The BX stent-graft appears safe and effective in F/B-EVAR, with satisfying preliminary results. Larger studies with longer follow-up are required to confirm BX durability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Preliminary experience with the low profile VBX as bridging stent-graft in fenestrated and branched endovascular aortic repair — Science Skim