The Journal of arthroplasty

Complications and Failures following Extensor Mechanism Reconstruction in Revision Total Knee Arthroplasty.

Gregory J Kirchner, Davis Lee, Randall R Rainwater, Simon C Mears, Jeffrey B Stambough, Benjamin M Stronach

Department of Orthopaedic Surgery, Adult Reconstruction, University of Arkansas for Medical Sciences, Little Rock, Arkansas. Electronic address: gkirchner@uams.edu. · College of Medicine, University of Arkansas for Medical Sciences, Little Rock, Arkansas. Electronic address: DMLee@uams.edu.

Key points

From the paper's conclusion
  • Patients who had EMR had an increased risk of wound dehiscence in both septic (odds ratio (OR) 2.27, 95% confidence interval (CI) 1.11 to 5.00) and aseptic (OR 5.00, 95% CI 3.33 to 10.00) revision TKA. The odds of subsequent debridement, skin grafting, and amputation or fusion were similar in septic revision TKA regardless of EMR status; however, in aseptic revision TKA, EMR was associated with increased odds of subsequent debridement (OR 2.56, 95% CI 1.67 to 3.33), skin grafting (OR 3.45, 95% CI 1.67 to 10.00), flap procedure (OR 4.55, 95% CI 2.00 to 10.00), and amputation (OR 4.17, 95% CI 1.11 to 10.00). Multivariate analysis of all revision TKAs demonstrated that the risk of amputation was associated with debridement (Likelihood ratio (LR) 5.97, P < 0.0001) and EMR (LR 3.24, P = 0.0008). In revision TKA with EMR, amputation was associated with flap use (LR 29.79, P = 0.18) and debridement (LR 4.52, P = 0.11).

Abstract

INTRODUCTION: Failure of the extensor mechanism following total knee arthroplasty (TKA) is a devastating complication that compromises function and patient satisfaction. The incremental risk of concomitant extensor mechanism reconstruction (EMR) during revision TKA on wound complications, reoperation, and ultimate treatment failure, including arthrodesis or amputation, remains limited. METHODS: Using a national claims database, we identified patients who underwent revision TKA with or without preoperative periprosthetic joint infection. Outcomes of patients who underwent revision TKA with or without EMR were compared using Chi-square analyses. Multivariate analyses identified independent predictors of 2-year fusion or amputation. RESULTS: Patients who had EMR had an increased risk of wound dehiscence in both septic (odds ratio (OR) 2.27, 95% confidence interval (CI) 1.11 to 5.00) and aseptic (OR 5.00, 95% CI 3.33 to 10.00) revision TKA. The odds of subsequent debridement, skin grafting, and amputation or fusion were similar in septic revision TKA regardless of EMR status; however, in aseptic revision TKA, EMR was associated with increased odds of subsequent debridement (OR 2.56, 95% CI 1.67 to 3.33), skin grafting (OR 3.45, 95% CI 1.67 to 10.00), flap procedure (OR 4.55, 95% CI 2.00 to 10.00), and amputation (OR 4.17, 95% CI 1.11 to 10.00). Multivariate analysis of all revision TKAs demonstrated that the risk of amputation was associated with debridement (Likelihood ratio (LR) 5.97, P < 0.0001) and EMR (LR 3.24, P = 0.0008). In revision TKA with EMR, amputation was associated with flap use (LR 29.79, P = 0.18) and debridement (LR 4.52, P = 0.11). DISCUSSION: In this large database study, EMR in aseptic revision TKA patients was independently associated with increased risk of amputation, likely due to the higher burden of soft-tissue procedures. In septic revision TKA, amputation risk was higher than aseptic revision TKA regardless of EMR.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers