The Journal of arthroplasty

Outcomes of Rotating Hinge Knee Implants in Revision Total Knee Arthroplasty: Instability as a Potential Risk Factor for Mechanical Failure.

Antoine Vincent, Elvire Servien, Sébastien Lustig, Cécile Batailler

Orthopaedics surgery and Sports Medicine Department, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France. Electronic address: antoine.vincent@chu-lyon.fr. · Orthopaedics surgery and Sports Medicine Department, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France; LIBM - EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France. Electronic address: elvire.servien@chu-lyon.fr.

Observational · n=230

Key points

From the paper's conclusion
  • The RTKA with RHK implants provided acceptable survival rates, but with a high risk of complications. An RTKA performed for instability represents a particularly high-risk scenario, requiring optimized surgical planning and implant selection to minimize the risk of mechanical failure.

Abstract

PURPOSE: Revision total knee arthroplasties (RTKA) with rotating hinged knee (RHK) implants are increasingly used in complex cases. Despite advances in implant design, the complication rate remains a major concern regarding RHK implants. This study aimed to assess the complications, revisions, survival rates, and potential risk factors of failure after RTKA with RHK at a minimum follow-up of two years. METHODS: This retrospective, single-center study included 230 patients who underwent RTKA with RHK implants between 2010 and 2021. An RHK was implanted in cases of collateral ligament insufficiency, severe bone loss, some periprosthetic fractures, severe stiffness, or extensive debridement for infection. The mean age was 69 years (range, 43 to 92). The mean body mass index (BMI) was 30.8 (range, 13.8 to 54.7). Survival rates were analyzed using Kaplan-Meier methods based on the following endpoints: all-cause and mechanical cause revisions. Multinomial logistic regression was used to identify risk factors for implant failure. The mean follow-up was 55.2 months (range, 24.6 to 166.8). RESULTS: Aseptic loosening was observed in 6.1% of cases (n = 14), dislocation in 3% (n = 7), and extensor mechanism rupture in 3.0% (n = 7). The overall implant survival rates were 79.2% at five years and 67.3% at 10 years for all-cause revisions and 85.0% at five years and 74.7% at 10 years for mechanical revisions. The instability as a cause of RTKA was a significant risk factor for mechanical revision (P = 0.019). A BMI below 30 was associated with a decreased risk of reoperations (P = 0.014). There were no significant risk factors that were identified for all-cause revisions. CONCLUSION: The RTKA with RHK implants provided acceptable survival rates, but with a high risk of complications. An RTKA performed for instability represents a particularly high-risk scenario, requiring optimized surgical planning and implant selection to minimize the risk of mechanical failure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers