The Journal of arthroplasty

Extensor Mechanism Reconstruction Using Allograft Versus Synthetic Mesh: A Systematic Review and Meta-Analysis.

Carlo Mannina, Alexis Driscoll, Sophia Griffin, John Mazzocco, Seleem Elkadi, Daniel Sun

Tufts University School of Medicine, 145 Harrison Ave, Boston, MA, 02111, USA. · Department of Orthopaedic Surgery, Tufts Medical Center, Biewend Building, 260 Tremont St, Boston, MA 02111, USA.

Meta-analysis

Key points

From the paper's conclusion
  • Allograft and synthetic mesh have similar functional outcomes, failure rates, and complication rates when used for EMR following TKA.

Abstract

BACKGROUND: There is no clear best technique for extensor mechanism reconstruction (EMR) after total knee arthroplasty (TKA). The purpose of this article was to compare the outcomes of EMR after TKA with allograft versus synthetic mesh. METHODS: There were three databases queried for all articles published prior to December 17, 2025. Articles that investigated EMR after TKA with allograft or synthetic mesh and reported clinical outcomes were included. Studies with less than one year of follow-up were excluded. Meta-analyses were performed using restricted maximum likelihood random-effects models, reported in proportions with 95% confidence intervals. A total of 25 articles were included: six mesh, 17 allograft, and two comparative. A total of 496 knees were included, 106 mesh and 390 allograft. The average age was 68 years (range, 61.0 to 74.0), and the average follow-up was 48.1 months (range, 19.0 to 82.7). RESULTS: During EMR, 46 patients in the mesh group underwent revision TKA and 130 in the allograft group, and patellar resurfacing was not performed in most patients. Similar Knee Society Scores, Knee Injury and Osteoarthritis Outcome Scores, failure rates, extensor lag rates, revision rates, and complication rates were found between the two groups. The pooled failure rate of the allograft group was 30.6% (95% confidence interval [CI], 24.6 to 37.3; I2 = 4.56%), while the failure rate of the mesh group was 37.5% (95% CI, 24.4 to 52.6; I2 = 0.00%). Complications primarily included infection, periprosthetic fracture, bone block revision, persistent extension deficit, and re-rupture. The overall complication rate, including infection, was 21.2% (95% CI, 12.0 to 34.6; I2 = 65.33%) for the allograft group and 16.4% (95% CI, 9.3 to 27.3; I2 = 9.60%) for the mesh group. CONCLUSIONS: Allograft and synthetic mesh have similar functional outcomes, failure rates, and complication rates when used for EMR following TKA.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers