Extensor Mechanism Allograft After Total Knee Arthroplasty: An Effective Procedure With a Major Risk of Complications.
Martin Ecki, Etienne Deroche, Elvire Servien, Sébastien Lustig, Cécile Batailler
Orthopaedic department, Saint-Pierre Ottignies Clinic, 1340 Ottignies-Louvain-la-Neuve, Belgium. Electronic address: martin.ecki92@gmail.com. · Orthopaedics surgery and Sports Medicine Department, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.
Key points
From the paper's conclusion- Extensor mechanism allograft on TKA was a salvage procedure, with a satisfactory mid-term allograft survival rate. However, this procedure was associated with major morbidity and modest functional outcomes.
Abstract
PURPOSE: Chronic extensor mechanism rupture is a rare but dreaded complication of total knee arthroplasty (TKA). This study aimed to describe the functional outcomes, survival rates, complications, and revisions after complete extensor mechanism allograft (EMA) on TKA at a minimal follow-up of two years. METHODS: This retrospective single-center study included all patients who underwent complete EMA after a TKA between 2017 and 2022, who had a minimum follow-up of 24 months (range, 24.0 to 85.0). Of the 60 EMAs, 51 knees were included. The mean patient age was 66 years (range, 49.9 to 81.4). Most extensor mechanism ruptures were on the patellar tendon (39.2%) and the quadricipital tendon (33.3%). This cohort was divided into two subgroups: EMA with (n = 20) or without (n = 31) simultaneous RTKA. Allograft failure was defined by an active extension deficit (AED) superior to 30° or a revision of the allograft because of its rupture. The analysis focused on the rate of mechanical and septic complications, survival without allograft revision, and functional outcomes. RESULTS: The mean follow-up was 39.8 months ±15.6. The mean deficit of AED was 22.0° ± 24.4. At the last follow-up, 37.3% of the patients had an AED superior to 30° or an EMA rupture. The Kaplan-Meier survival without aseptic EMA failure (EMA revision and AED > 30°) at 24 and 48 months was 79.5 and 59.1%, respectively. At the last follow-up, 52.9% of the patients were satisfied. There were 15 complications (29.4%) on the EMA, with nine surgical reoperations for EMA failure (17.6%). CONCOMITANT: TKA revision did not affect functional outcomes, mechanical complication rates, or allograft survival. The QT rupture subgroup had a significantly hixgher risk of EMA failure, particularly on the quadriceps tendon (P = 0.045). CONCLUSION: Extensor mechanism allograft on TKA was a salvage procedure, with a satisfactory mid-term allograft survival rate. However, this procedure was associated with major morbidity and modest functional outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Extensor Mechanism Reconstruction Using Allograft Versus Synthetic Mesh: A Systematic Review and Meta-Analysis.The Journal of arthroplasty · 2026
- Complications and Failures following Extensor Mechanism Reconstruction in Revision Total Knee Arthroplasty.The Journal of arthroplasty · 2026
- Outcomes of Rotating Hinge Knee Implants in Revision Total Knee Arthroplasty: Instability as a Potential Risk Factor for Mechanical Failure.The Journal of arthroplasty · 2026
- Clinical and radiological outcomes of primary semi-constrained total elbow arthroplasty at 10-year mean follow-up.Clinics in shoulder and elbow · 2026
- Extensor Mechanism Reconstruction Following Periprosthetic Joint Infection After Total Knee Arthroplasty: A Systematic Review.Cureus · 2026
- Proximal Realignment of the Extensor Mechanism During Total Knee Arthroplasty for Chronic Patellar Dislocation in Knee Arthritis: Results at a Median Follow-Up of Four Years.The Journal of arthroplasty · 2026