The Journal of arthroplasty

Extensor Mechanism Allograft After Total Knee Arthroplasty: An Effective Procedure With a Major Risk of Complications.

Martin Ecki, Etienne Deroche, Elvire Servien, Sébastien Lustig, Cécile Batailler

Orthopaedic department, Saint-Pierre Ottignies Clinic, 1340 Ottignies-Louvain-la-Neuve, Belgium. Electronic address: martin.ecki92@gmail.com. · Orthopaedics surgery and Sports Medicine Department, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.

Observational

Key points

From the paper's conclusion
  • Extensor mechanism allograft on TKA was a salvage procedure, with a satisfactory mid-term allograft survival rate. However, this procedure was associated with major morbidity and modest functional outcomes.

Abstract

PURPOSE: Chronic extensor mechanism rupture is a rare but dreaded complication of total knee arthroplasty (TKA). This study aimed to describe the functional outcomes, survival rates, complications, and revisions after complete extensor mechanism allograft (EMA) on TKA at a minimal follow-up of two years. METHODS: This retrospective single-center study included all patients who underwent complete EMA after a TKA between 2017 and 2022, who had a minimum follow-up of 24 months (range, 24.0 to 85.0). Of the 60 EMAs, 51 knees were included. The mean patient age was 66 years (range, 49.9 to 81.4). Most extensor mechanism ruptures were on the patellar tendon (39.2%) and the quadricipital tendon (33.3%). This cohort was divided into two subgroups: EMA with (n = 20) or without (n = 31) simultaneous RTKA. Allograft failure was defined by an active extension deficit (AED) superior to 30° or a revision of the allograft because of its rupture. The analysis focused on the rate of mechanical and septic complications, survival without allograft revision, and functional outcomes. RESULTS: The mean follow-up was 39.8 months ±15.6. The mean deficit of AED was 22.0° ± 24.4. At the last follow-up, 37.3% of the patients had an AED superior to 30° or an EMA rupture. The Kaplan-Meier survival without aseptic EMA failure (EMA revision and AED > 30°) at 24 and 48 months was 79.5 and 59.1%, respectively. At the last follow-up, 52.9% of the patients were satisfied. There were 15 complications (29.4%) on the EMA, with nine surgical reoperations for EMA failure (17.6%). CONCOMITANT: TKA revision did not affect functional outcomes, mechanical complication rates, or allograft survival. The QT rupture subgroup had a significantly hixgher risk of EMA failure, particularly on the quadriceps tendon (P = 0.045). CONCLUSION: Extensor mechanism allograft on TKA was a salvage procedure, with a satisfactory mid-term allograft survival rate. However, this procedure was associated with major morbidity and modest functional outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers