Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Chest computed tomography for oncological follow-Up: Clinical relevance and importance of dosimetric evaluation.

C C P Fontainha, L L S Ramos, L B Nogueira, B C Silva

Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena, 190, Belo Horizonte, 30130-100, MG, Brazil. Electronic address: crissia@gmail.com. · Universidade Federal de Minas Gerais, Curso de Radiologia, Av. Prof. Alfredo Balena, 190, Belo Horizonte, 30130-100, MG, Brazil.

Observational · n=1,177

Key points

From the paper's conclusion
  • These findings reinforce the importance of continuous dosimetric monitoring to optimize CT protocols and ensure radiation protection in oncological patients.

Abstract

Computed tomography (CT) is widely used in oncology for diagnosis, treatment planning, staging, follow-up, and assessment of disease extent. Diagnostic Reference Levels (DRLs) recommend dosimetric metrics based on volume CT dose index (CTDIvol), dose-length product (DLP), while effective dose (E) was estimated as a complementary indicator for radiation dose comparison and population-based risk assessment. This retrospective study evaluated the importance of chest CT in oncological indications at a public hospital and assessed dosimetrics for radiation protection monitoring. Chest CT examinations performed in elective outpatients during 2025 were analyzed. In the studied sample (n = 1177), almost 64% of patients had oncological clinical indications, with a mean age of 63.69 ± 13.80 years; around 45% were female and 55% male. Dosimetric parameters were obtained from two 64-slice scanners: PHILIPS INCISIVE (CTA) and CANON AQUILION (CTB). Median DLP and CTDIvol values, respectively, were 190.02 mGy cm and 5.24 mGy (CT A), and 146.28 mGy cm and 6.48 mGy (CTB). Effective dose values were 2.67 ± 0.84 mSv (CTA) and 2.36 ± 1.23 mSv (CTB). For oncological chest CT examinations (n=172), CT A presented P25/P50/P75 values of 4.17/5.24/6.21 mGy for CTDIvol and 150.61/190.02/222.70 mGy cm for DLP, whereas CT B presented corresponding values of 3.43/6.48/8.74 mGy for CTDIvol and 91.18/138.93/199.94 mGy cm for DLP. All values remained below International Commission on Radiological Protection (ICRP) reference levels. CTB showed higher dose indices, likely related to a higher tube current-time product. These findings reinforce the importance of continuous dosimetric monitoring to optimize CT protocols and ensure radiation protection in oncological patients. Chest CT remains essential for metastatic evaluation and oncological patient management.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers