Journal of applied clinical medical physics

Leveraging longitudinal ACR CT Dose Index Registry data to improve interpretation of institutional CT dose performance.

Azmul H Siddique, Mike Weaver, Gary Ge, Leslie Anaskevich, Jie Zhang

Department of Radiology, University of Kentucky, Lexington, Kentucky, USA.

Observational

Key points

From the paper's conclusion
  • This supports improved interpretation of institutional CT dose performance and targeted exam triage.

Abstract

BACKGROUND: The American College of Radiology CT Dose Index Registry (DIR) is a national benchmarking program that enables institutions to compare CT dose metrics with aggregated reference distributions to support CT radiation dose optimization and quality assurance. In practice, benchmarking is typically reviewed at discrete reporting intervals, which can be limited by benchmark shifts, transient variation, or incomplete reference data. PURPOSE: This study evaluates how longitudinal DIR analysis improves interpretation of institutional CT dose performance and supports protocol optimizations. METHODS: Longitudinal DIR data from 2020 to 2025 were analyzed for 10 common CT exams across 21 reporting quarters for both adult and pediatric. CTDIvol, DLP, and SSDE distributions (25th, 50th, 75th percentiles) were compared with exam-specific DIR reference percentiles. Exams with n ≥ 30 per reporting interval were included for analysis. Exceedance rates, defined as the median value of facility metric exceeding the DIR 75th percentile (Diagnostic Reference Level [DRL]), were evaluated across exams and reporting intervals. Linear mixed-effects (LME) regression was used to evaluate longitudinal trends and identify exams demonstrating statistically significant dose drift. Coefficient of variation (CV) and F-test were performed to assess year-to-year variability. RESULTS: Four of ten adult exams remained within DRL across all intervals for both CTDIvol and DLP. CT Neck with IV contrast exceeded the CTDIvol and DLP DRLs in 19/21 intervals, and CT C-spine without IV contrast exceeded the DLP DRL in 19/21 intervals. Pediatric data demonstrated exceedance rates greater than 50% for both CTDIvol and DLP in those same exams. For adult exams with seven available DIR SSDE benchmarks, five remained within the SSDE DRL across all intervals. LME analysis identified a significant increase in institutional dose metrics in 2025 (β2 = 0.139; p = 0.001), with CT C-Spine contributing largest positive shift (30.56%) for adults. Facility median variability (CV) ranged from 4.6%-127%, whereas DIR 75th percentile variability ranged from 2.8% to 21.9%. CONCLUSION: Longitudinal analysis of ACR DIR executive summary data extends isolated quarterly review by contextualizing exceedances over time, accounting for benchmark variability, and distinguishing persistent exam behavior from transient effects. This supports improved interpretation of institutional CT dose performance and targeted exam triage.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers