Breast cancer staging and follow-up: Contributions of chest computed tomography and dosimetric analysis.
C C P Fontainha, R C O Soares, L B Nogueira, B C Silva
Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena, 190, Belo Horizonte, 30130-100, MG, Brazil. Electronic address: crissia@gmail.com. · Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena, 190, Belo Horizonte, 30130-100, MG, Brazil.
Key points
From the paper's conclusion- The P75 values remained below international DRLs for adult chest CT and CT for radiotherapy planning.
Abstract
Breast cancer is the second most common malignant neoplasm among women worldwide. Computed tomography (CT) plays an important role in diagnosis, staging, follow-up, and metastatic assessment. This study aimed to evaluate the role of chest CT in patients with breast neoplasms at a public hospital and to compare dosimetric parameters with Diagnostic Reference Levels (DRLs), based on CTDIvol and dose-length product (DLP). Related malignancies (ovarian and cervical) were included for preliminary analysis. A retrospective study of 334 elective outpatient chest CT examinations performed in 2025 was conducted. All patients were female, with a mean age of 59.04 ± 12.57 years, and most (65.40%) were within the recommended screening age range (50-74 years), while 15.19% were aged 40-49 years. DICOM data were obtained from two 64-slice CT scanners: Philips Incisive (CT A) and Canon Aquilion (CT B). CTDIvol and DLP values for CT A were stratified by clinical indication. Percentile analysis (P25-P75) showed lower CTDIvol values for CT A (4.06-5.82 mGy) compared with CT B (4.99-8.83 mGy), while DLP values were higher in CT A (146.97-201.45 mGy cm) than in CT B (94.51-201.49 mGy cm). Median CTDIvol values were 4.70 and 7.65 mGy, and DLP values were 169.42 and 141.36 mGy cm for CT A and CT B, respectively. The P75 values remained below international DRLs for adult chest CT and CT for radiotherapy planning. These findings highlight the importance of continuous dosimetric assessment to optimize CT protocols and ensure radiation protection in patients undergoing treatment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Chest computed tomography for oncological follow-Up: Clinical relevance and importance of dosimetric evaluation.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Doses in planning computed tomography in one radiotherapy department: Description of exposure parameters and estimation of organ doses, effective doses and typical doses.Radiography (London, England : 1995) · 2026
- The impact of breast shielding on radiation dose during computed tomography procedures.Radiation protection dosimetry · 2026
- CT protocol optimisation for oncologic surveillance imaging: phantom-based comparison of multi-scan and single-scan acquisition strategies.Biomedical physics & engineering express · 2026
- Systemic staging in locoregional breast cancer recurrence: Do Contrast-Enhanced CT and Bone Scintigraphy Still Add Value?The British journal of radiology · 2026
- Comparison of breast-level surface dose between single-energy CT and fast kilovoltage-switching dual-energy CT under matched CTDIvol conditions: a chest phantom study.Radiological physics and technology · 2026