Corneal versus refractive surgically induced astigmatism: vector analysis of their dissociation and implications for toric IOL planning.
Klemens P Kaiser, Jascha A Wendelstein, Jodhbir S Mehta, Jakob Wend, Philipp Necpal, Achim Langenbucher, Thomas Kohnen
Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany.; Singapore National Eye Centre, Singapore, Singapore.; Regenerative Therapy Research Group, Singapore Eye Research Institute, Singapore, Singapore. · Institute for Refractive- and Ophthalmic Surgery (IROC), Zurich, Switzerland; Department of Experimental Ophthalmology, Saarland University, Homburg, Germany.
Key points
From the paper's conclusion- The per-eye tSIA was uncorrelated with the refractive SIA and carried no systematic direction, as power vectors or flattening effect, which stayed below a quarter of a toric cylinder step. ORA preceded surgery and remained systematically stable. Individually measured tSIA has only limited value for toric IOL planning.
Abstract
PURPOSE: To determine whether tomographically measured surgically induced astigmatism (SIA) is reflected in the manifest refraction, and whether the ocular residual astigmatism (ORA) precedes surgery and is stable per eye. DESIGN: Single-center, longitudinal, comparative vector analysis. METHODS: Eyes underwent non-toric intraocular lens (IOL) or phakic implantable collamer lens (ICL) implantation. Total corneal refractive power (Pentacam) and manifest subjective refractive astigmatism at the corneal plane were expressed as Cartesian double-angle power vectors before and 3 months after surgery, yielding tomographic SIA (tSIA), refractive SIA (rSIA), their vector difference ΔSIA, and the pre- and postoperative ORA. Each SIA was decomposed into its flattening effect and torque at the incision meridian. Centroids were tested against the null by eye side. RESULTS: Of 290 eyes (256 IOL; 34 ICL), tSIA magnitude was small (IOL 0.47D; ICL 0.34-0.39D) with centroids near null. ΔSIA had a large mean magnitude (IOL 0.74-0.88D) but a near-origin centroid, significant only in IOL right eyes. Mean corneal flattening effect (+0.008D right, +0.140D left eyes) did not predict its refractive counterpart. ORA did not differ between cohorts (-0.11D, 95%-CI -0.25 to +0.02) and remained significant postoperatively, yet per eye only half the offset persisted in phakic and less in pseudophakic eyes. CONCLUSIONS: The per-eye tSIA was uncorrelated with the refractive SIA and carried no systematic direction, as power vectors or flattening effect, which stayed below a quarter of a toric cylinder step. ORA preceded surgery and remained systematically stable. Individually measured tSIA has only limited value for toric IOL planning.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Vector Analysis of Surgically Induced Astigmatism for Individualized Superior Incision Selection in ICL Surgery: Real-World Outcomes of Corneal and Limbal Incisions Stratified by Preoperative Astigmatism.Journal of ophthalmology · 2026
- Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation.Journal of clinical medicine · 2026
- Early Visual Outcomes of Toric Versus Non-Toric IOLs in Low-to-Moderate Corneal Astigmatism: A Real-World Matched Cohort Study.Journal of clinical medicine · 2026
- Clinical Performance of an Isofocal Toric Intraocular Lens with Double C-Loop Haptics: A Multicenter Retrospective Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Rotational stability and visual outcomes of toric implantable collamer lenses in eyes with horizontal and non-horizontal implanting orientation: an observational study.International ophthalmology · 2026
- Incision-induced astigmatic changes in eyes undergoing simultaneous phakic intraocular lens explantation and phacoemulsificationJournal of Cataract & Refractive Surgery · 2026