Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation.
Teresa Laborda-Guirao, Christian Hierro-Cordón, José María Sánchez-González, Timoteo González-Cruces
Department of Glaucoma and Neuro-Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain. · Department of Information Technology, Hospital Arruzafa, 14012 Cordoba, Spain.
Key points
From the paper's conclusion- Conclusions: Combined assessment of R, Rw, and CV provides a quantitative framework for determining whether a mean SIA adequately represents its underlying vector distribution before incorporation into toric IOL calculators.
Abstract
Background: Surgeon-specific surgically induced astigmatism (SIA) is commonly considered in toric intraocular lens (IOL) calculations; however, a mean SIA vector does not indicate whether the underlying surgical effect is reproducible across cases. Methods: We developed a quantitative framework based on axial circular statistics to characterize SIA reproducibility. Directional consistency was assessed using the mean resultant length (R), while a magnitude-weighted extension (Rw) quantified whether the astigmatic power was concentrated around a predominant direction. Variability in scalar SIA magnitude was independently assessed using the coefficient of variation (CV). Theoretically derived operational thresholds were established from geometric and relative-dispersion criteria and integrated into a decision framework. A controlled synthetic simulation using Barrett Toric calculations compared higher- and lower-consistency SIA distributions across 20 matched ocular profiles at each of two centroid magnitudes, estimating final theoretical residual astigmatism under a common-plane approximation. Results: R and Rw provide complementary normalized measures of directional reproducibility, whereas CV captures variability in SIA magnitude. A threshold of 0.70 for R and Rw was geometrically derived from 1/2, corresponding to a symmetric ±22.5° deviation around the predominant clinical astigmatic axis. CV thresholds of <20%, 20-50%, and >50% were proposed to represent low, intermediate, and high relative magnitude variability, respectively. Higher SIA consistency yielded lower mean final theoretical residual astigmatism at both centroid magnitudes: 0.25 versus 0.51 D for the 0.26 D centroid and 0.42 versus 0.90 D for the 0.55 D centroid. Conclusions: Combined assessment of R, Rw, and CV provides a quantitative framework for determining whether a mean SIA adequately represents its underlying vector distribution before incorporation into toric IOL calculators. These theoretically derived thresholds require subsequent clinical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Planning Adjustment of Toric Capsular Bag Intraocular Lens Axis to Minimise Refractive Cylinder Outcome—A Calculation Concept Based on Vergence TransformationsDiagnostics · 2026
- Vector Analysis of Surgically Induced Astigmatism for Individualized Superior Incision Selection in ICL Surgery: Real-World Outcomes of Corneal and Limbal Incisions Stratified by Preoperative Astigmatism.Journal of ophthalmology · 2026
- Corneal versus refractive surgically induced astigmatism: vector analysis of their dissociation and implications for toric IOL planning.American journal of ophthalmology · 2026
- Residual Astigmatism With Toric Versus Light-Adjustable Intraocular Lenses: A Power-Vector Model of the Effect of Alignment Uncertainty.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Use of the internal astigmatism axis to determine the toric intraocular lens axis: Comparison between C-loop and plate-haptic lenses.Arquivos brasileiros de oftalmologia · 2026
- Agreement of keratometry measurements for toric IOL planning in routine clinical practice: KR-800, IOLMaster 500, and Pentacam HR.PloS one · 2026