Academic radiology

Three-Dimensional T2-Weighted Variable Flip-Angle Turbo Spin Echo for Cervical Spine MRI at 0.55 T: A Feasibility Study.

Bochao Li, Jay Acharya, Jordan S Gross, Steven Y Cen, Brian A Hargreaves, Krishna S Nayak

Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California (B.L., K.S.N.). Electronic address: bochaoli@usc.edu. · Diagnostic Radiology, University of California Los Angeles, Los Angeles, California (J.A., J.S.G.).

Key points

From the paper's conclusion
  • 3D SPACE at 0.55 T is feasible for cervical spine MRI in healthy subjects and post-ACDF subjects with titanium instrumentation. Although diagnostic performance was not evaluated, the preliminary findings suggest potential advantages of SPACE, including higher SNR/CNR efficiency, improved CSF signal homogeneity with reduced CSF pulsation artifacts, and improved nerve root visualization, supporting further evaluation.

Abstract

RATIONALE AND OBJECTIVES: To evaluate the feasibility of three-dimensional T2-weighted sampling perfection with application-optimized contrasts using different flip angle evolutions (SPACE) for cervical spine magnetic resonance imaging (MRI) at 0.55 T and to preliminarily compare image quality with conventional two-dimensional T2-weighted turbo spin echo (TSE) in healthy volunteers and post-anterior cervical discectomy and fusion (ACDF) subjects. MATERIALS AND METHODS: Five healthy volunteers (26.6 ± 2.9 years) and five post-ACDF subjects with titanium implants (63.6 ± 7.2 years) underwent cervical spine MRI at 0.55 T using sagittal TSE, axial TSE, and sagittal SPACE. Quantitative analysis included signal-to-noise ratio (SNR) efficiency and cerebrospinal fluid (CSF)-to-spinal cord (SC) contrast-to-noise ratio (CNR) efficiency. Two board-certified radiologists independently evaluated perceived SNR, CSF pulsation artifacts, motion artifacts, visualization of ten anatomical structures, and metal artifact severity using a 5-point Likert scale. Quantitative sequence comparisons were performed using exact paired Wilcoxon signed-rank tests at the subject level. Qualitative 5-point scores were analyzed separately by cohort and category using linear mixed-effects models that accounted for subject and reader clustering. RESULTS: 3D SPACE demonstrated higher SNR efficiency than 2D TSE for both CSF and SC in both cohorts. CSF-SC CNR efficiency was higher with SPACE. In healthy subjects, 3D SPACE received higher reader scores for intraspinal nerve root visualization and CSF pulsation artifact reduction. In post-ACDF subjects, 3D SPACE received higher reader scores for nerve root visualization, whereas metal-artifact scores and other qualitative metrics did not show clear sequence-related differences. CONCLUSION: 3D SPACE at 0.55 T is feasible for cervical spine MRI in healthy subjects and post-ACDF subjects with titanium instrumentation. Although diagnostic performance was not evaluated, the preliminary findings suggest potential advantages of SPACE, including higher SNR/CNR efficiency, improved CSF signal homogeneity with reduced CSF pulsation artifacts, and improved nerve root visualization, supporting further evaluation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Three-Dimensional T2-Weighted Variable Flip-Angle Turbo Spin Echo for Cervical Spine MRI at 0.55 T: A Feasibility Study — Science Skim