Incremental Diagnostic Value of Zero-Echo-Time Magnetic Resonance Imaging for Osseous Cervical Neural Foraminal Stenosis: A Retrospective Multireader Study.
Jiandong Guo, Shasha Zeng, Wenke Tang, Tiejun Zhang, Shilong Zhuang, Jichao Zhu, Ping Xiao, Yafen Li,
Department of Radiology, Shenzhen Hospital (Futian) of Guangzhou University of Chinese Medicine, 6001 Beihuan Avenue, Futian District, Shenzhen 518000, China. · Laboratory of Molecular Imaging and Medical Intelligence, Department of Radiology, Longgang Central Hospital of Shenzhen; Shenzhen Clinical Medical College, Guangzhou University of Chinese Medicine; Longgang Clinical Institute of Shantou University Medical College, 6082 Longgang Avenue, Longgang District, Shenzhen 518116, China.
Key points
From the paper's conclusion- We evaluated whether adding zero-echo-time (ZTE) imaging improves detection of CT-defined grade ≥2 foraminal stenosis.
Abstract
Background/Objectives: Conventional cervical magnetic resonance imaging (MRI) depicts cortical bone poorly, whereas computed tomography (CT) adds radiation exposure. We evaluated whether adding zero-echo-time (ZTE) imaging improves detection of CT-defined grade ≥2 foraminal stenosis. Methods: This single-centre retrospective diagnostic accuracy study included 81 consecutive eligible patients evaluated between October 2024 and June 2025 who underwent cervical MRI and CT within 14 days. Two blinded musculoskeletal radiologists graded 810 foramina from C2-C3 through C6-C7 using conventional MRI and MRI + ZTE. A study-specific scale incorporated narrowing, nerve-root morphology, and surrounding fat appearances. Consensus CT grading was the reference standard; grade ≥2 defined a positive foramen. Paired differences were assessed with patient-clustered bootstrap resampling. Results: Mean age was 48.9 ± 13.6 years; 55 patients were women. CT identified grade ≥2 stenosis in 150/810 foramina (18.5%). Adding ZTE increased sensitivity from 68.7% to 87.3% for Reader 1 and from 17.3% to 35.3% for Reader 2. Sensitivity differences were 18.7 percentage points (95% confidence interval [CI], 10.6-27.1) and 18.0 percentage points (95% CI, 6.6-30.3), respectively. Specificity increased from 90.5% to 96.8% and from 96.7% to 97.6%, respectively. Areas under the receiver operating characteristic curve increased by 0.115 (95% CI, 0.076-0.164) and 0.121 (95% CI, 0.061-0.184). Binary interreader agreement increased numerically from κ = 0.25 to κ = 0.41. Conclusions: Adding ZTE improved detection of CT-defined grade ≥2 foraminal stenosis, although sensitivity remained low for one reader. Effects on CT use, management decisions, and clinical outcomes require prospective evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of zero-echo time (ZTE) MRI for preoperative evaluation of cervical OPLL complicated with dural ossification (DO): a retrospective study.Skeletal radiology · 2026
- Quantitative Evaluation of Cervical Spine Morphometry: Zero Echo Time MRI Versus Multislice CT.Journal of magnetic resonance imaging : JMRI · 2026
- Deep Learning-Augmented Zero Echo Time MRI Increases Diagnostic Confidence for Osseous Assessment in Hand and Foot MRI Protocols.Diagnostics (Basel, Switzerland) · 2026
- Pars defect detection with 3 T GE ZeroTE bone MRI in children, adolescents and young adults with low back pain: a pilot study of inter-rater reproducibility and CT-linked feasibility.Skeletal radiology · 2026
- A Preliminary Study of MRI with Zero Echo Time Sequence for Combined Fracture and Rotator Cuff Assessment in Proximal Humerus Fractures.Journal of shoulder and elbow surgery · 2026
- Virtual non-calcium dual-energy computed tomography for postoperative lumbar spine evaluation following pedicle screw instrumentation.Diagnostic and interventional radiology (Ankara, Turkey) · 2026