Perioperative adverse events and device malfunctions associated with ROSA cranial stereotactic robotic surgery a descriptive analysis of FDA MAUDE reports from 2016 to 2026.
Zisu Zhai, Mohan Shi, Dan Gao, Lei Cao
Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China. · Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China. caolei_163@163.com.
Key points
From the paper's conclusion- We characterized perioperative adverse events and device malfunctions involving ROSA cranial stereotactic robotic systems in the US Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database.
Abstract
We characterized perioperative adverse events and device malfunctions involving ROSA cranial stereotactic robotic systems in the US Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. Reports received from 1 January 2016 through 31 July 2026 were identified using ROSA-specific brand and 510(k) searches under FDA product code HAW, with date segmentation. In the frozen dataset, deduplication yielded 1,277 unique ROSA medical device reports (MDRs); 155 were excluded and 1,122 were analysed. Two reviewers independently coded reports, followed by third senior reviewer review. Descriptive results used final consensus classifications. The ROSA cohort contained 880 (78.4%) Malfunctions, 241 (21.5%) Injuries, and 1 (0.1%) Death. Software/imaging/data (455; 40.6%) and registration/accuracy/calibration (235; 20.9%) were the leading failure domains. No reported harm was coded in 1,057 (94.2%) MDRs. Restart/reboot/power-cycle was the leading management response (392; 34.9%), and procedure delay was the leading procedural outcome (529; 47.1%). ROSA reports frequently described software, imaging, registration, and workflow disruptions. These patterns can inform equipment checks, registration verification, troubleshooting, backup pathways, and training. Report proportions do not estimate harm incidence or establish causality. The partial 2026 interval is not comparable with complete calendar years.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Injury labels and patient-problem codes in FDA adverse event reports for robotic arthroplasty platforms: a cross-sectional analysis of 12,175 MAUDE reports.Journal of robotic surgery · 2026
- Failure modes of robotic-assisted arthroplasty platforms in Australia: a descriptive analysis of TGA adverse event reports.Journal of robotic surgery · 2026
- Laparoscopic and Robotic Device Malfunction: A Scoping Review.Journal of patient safety · 2026
- Device-procedure attribution of reported harm in robotic-assisted bronchoscopy: a MAUDE study informing safety surveillance of robotic surgical systems.Journal of robotic surgery · 2026
- Reported device problems and patient outcomes in da Vinci robotic robotic gastric and upper-gastrointestinal procedures: an FDA MAUDE database analysis.Journal of robotic surgery · 2026
- Device-related adverse event reports in robotic hernia repair: a disproportionality analysis of the FDA MAUDE database.Journal of robotic surgery · 2026