Journal of robotic surgery

Reported device problems and patient outcomes in da Vinci robotic robotic gastric and upper-gastrointestinal procedures: an FDA MAUDE database analysis.

Ping Song, Dawei Sun

Gastrointestinal Surgery Ward 1, Shengli Oilfield Central Hospital, Dongying, China. · Gastrointestinal Surgery Ward 1, Shengli Oilfield Central Hospital, Dongying, China. jasonsdw@163.com.

Observational

Key points

From the paper's conclusion
  • To describe reported device problems and patient outcomes in robotic gastric and upper-gastrointestinal procedures using the FDA Manufacturer and User Facility Device Experience (MAUDE) database.

Abstract

Robotic gastric and upper-gastrointestinal procedures include bariatric/metabolic operations, conventional/oncologic gastrectomy, and other procedures. Postmarket surveillance of reported device problems in this heterogeneous setting remains limited. To describe reported device problems and patient outcomes in robotic gastric and upper-gastrointestinal procedures using the FDA Manufacturer and User Facility Device Experience (MAUDE) database. We conducted a retrospective analysis of MAUDE reports from 2009 to 2025. Procedures were categorized as bariatric/metabolic, conventional/oncologic gastrectomy, or other/unspecified gastric or upper-gastrointestinal procedures. Device-problem descriptors, report characteristics, and report-level outcome associations were analyzed. Among 1,073 analyzed reports, device-problem descriptor profiles varied across reported platform categories. The da Vinci Xi category frequently included software or display descriptors, whereas the da Vinci Standard / Unspecified category frequently included stapling-related descriptors. In a procedure-adjusted multivariable model, Firing Problem (OR 9.53, 95% Wald CI 4.36-20.82), Misfire (OR 17.91, 95% Wald CI 7.10-45.21), and Failure to Form Staple (OR 17.59, 95% Wald CI 8.72-35.48) were associated with the selected severe-outcome indicator. Documentation/reporting factors were analyzed separately and were not interpreted as confirmed device malfunctions. This report-level analysis describes patterns of submitted device-problem descriptors and selected patient-outcome flags in robotic gastric and upper-gastrointestinal procedures. These associations are hypothesis-generating and do not establish device root cause, malfunction incidence, comparative safety, clinical effectiveness, or causal risk. Prospective, procedure-specific surveillance with standardized outcome adjudication and procedure-volume denominators is needed to evaluate device performance and clinical outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers