Impact of surgeon experience on the safety and accuracy of robot-assisted vs. navigation-guided percutaneous pedicle screw placement: a matched cohort study.
Paul Backhaus, Carolin Albrecht, Luisa Mona Kraus, Philipp Karschnia, Chiara Negwer, Bernhard Meyer, Arthur Wagner
Department of Neurosurgery, TUM School of Medicine and Health, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany. Paul.Backhaus@mri.tum.de. · Department of Neurosurgery, TUM School of Medicine and Health, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany.
Key points
From the paper's conclusion- Robot-assisted pedicle screw placement is safe and accurate, with comparable complication rates to conventional navigation. The observed increase in screw placement time may reflect the early adaptation phase of the robotic technique rather than an inherent limitation of the system. The descriptive reduction in revision rates among less experienced surgeons suggests a potential role for robotic assistance in supporting standardization and surgical training; however, this exploratory finding warrants confirmation in larger studies.
Abstract
PURPOSE: To compare intraoperative screw revision and outcomes of robot-assisted versus navigation-guided percutaneous pedicle screw placement and to explore whether outcomes differed by surgeon experience. MATERIALS AND METHODS: A prospective cohort of 43 consecutive patients undergoing robot-assisted percutaneous pedicle screw fixation between September 2024 and March 2026 was compared with a matched historical cohort of 129 patients treated using navigated conventional percutaneous instrumentation. Propensity score matching included age, sex, ASA physical status, anatomical region, surgical indication, and surgeon expertise. Surgeons were stratified according to prior spondylodesis case volume. Outcomes included screw revision rates (as a measure of screw accuracy), screw placement time, operative time, blood loss, and perioperative complications. RESULTS: Unadjusted screw-level revision proportions were 2.3% with robotic assistance and 3.5% with navigation-guided instrumentation. In adjusted patient-level analysis, greater surgeon experience, but not robotic assistance, was associated with fewer revisions. In the lowest-experience group, the proportions were descriptively 4.3% and 8.2%, but the technique-by-experience interaction was not statistically significant. Median screw-placement time was longer with robotic assistance (7.8 vs. 5.5 min per screw, p < 0.001). No statistically significant between-group differences were detected in blood loss, length of stay, or complication rates. CONCLUSION: Robot-assisted pedicle screw placement is safe and accurate, with comparable complication rates to conventional navigation. The observed increase in screw placement time may reflect the early adaptation phase of the robotic technique rather than an inherent limitation of the system. The descriptive reduction in revision rates among less experienced surgeons suggests a potential role for robotic assistance in supporting standardization and surgical training; however, this exploratory finding warrants confirmation in larger studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026
- Robot-assisted spinal surgery: technological maturity, clinical evidence, and future directions.Frontiers in robotics and AI · 2026
- Robot-assisted working-channel localization with automated entry-point planning in percutaneous endoscopic interlaminar discectomy: a prospective cohort study.Journal of robotic surgery · 2026
- Accuracy and influencing factors of robot-assisted sacroiliac screw placement: a comparative study of short versus trans-cortical screws.Journal of robotic surgery · 2026
- Comparative study of pedicle screw trajectory in scoliosis surgery: freehand technique versus navigated angular guidance using the PYTHEAS Your Guided Trajectory.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026