Journal of neuro-oncology

Application of augmented reality in frame-based stereotactic brain biopsy: a case series feasibility study.

Anton N Konovalov, Andrey E Bykanov, Dmitry N Okishev, Sergey A Maryashev, Tatiana S Bezbabicheva, Elisey A Trubnikov, Shokhzod G Tursunkulov, Anton A Artemyev,

Burdenko National Medical Research Center of Neurosurgery, Ministry of Health of the Russian Federation, Moscow, Russia. · Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), 8 Trubetskaya St., Bldg. 2, Moscow, 119048, Russia. iaerokhin.03@mail.ru.

Case report · n=10

Key points

From the paper's conclusion
  • Integrating AR navigation (HoloLens 2 and Medgital) with conventional frame-based STB is potentially technically feasible, safe, fast, and provides acceptable accuracy. AR complements the standard workflow by offering direct intraoperative visualization of the needle trajectory.

Abstract

PURPOSE: Frame-based stereotactic biopsy (STB) lacks intraoperative visual control. Augmented reality (AR) via Microsoft HoloLens 2 offers real-time visualization of the biopsy needle. This study evaluates the technical feasibility and preliminary clinical results of AR navigation during standard frame-based STB. METHODS: This prospective single-center pilot study included 10 adults undergoing STB for intracranial lesions. Standard trajectory planning utilized the Cosman-Roberts-Wells (CRW®) stereotactic frame, intraoperative computed tomography (CT), and preoperative magnetic resonance imaging (MRI) in NeuroSight Arc®. Concurrently, Medgital software and HoloLens 2 displayed a hologram of the patient's head, lesion, and trajectory. A passive tracker on the biopsy needle enabled real-time holographic visualization. Endpoints included technical feasibility, registration time, navigation error, diagnostic yield, and complications. RESULTS: AR navigation feasibility was confirmed in all 10 patients (100%). Mean registration time was 79 ± 27 s, and mean AR trajectory error relative to standard planning was 2.21 ± 0.67 mm. A definitive histological diagnosis was obtained in all 10 cases (mean passes: 2.4). No hemorrhagic complications or mortality occurred. CONCLUSION: Integrating AR navigation (HoloLens 2 and Medgital) with conventional frame-based STB is potentially technically feasible, safe, fast, and provides acceptable accuracy. AR complements the standard workflow by offering direct intraoperative visualization of the needle trajectory.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers