Application of augmented reality in frame-based stereotactic brain biopsy: a case series feasibility study.
Anton N Konovalov, Andrey E Bykanov, Dmitry N Okishev, Sergey A Maryashev, Tatiana S Bezbabicheva, Elisey A Trubnikov, Shokhzod G Tursunkulov, Anton A Artemyev,
Burdenko National Medical Research Center of Neurosurgery, Ministry of Health of the Russian Federation, Moscow, Russia. · Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), 8 Trubetskaya St., Bldg. 2, Moscow, 119048, Russia. iaerokhin.03@mail.ru.
Key points
From the paper's conclusion- Integrating AR navigation (HoloLens 2 and Medgital) with conventional frame-based STB is potentially technically feasible, safe, fast, and provides acceptable accuracy. AR complements the standard workflow by offering direct intraoperative visualization of the needle trajectory.
Abstract
PURPOSE: Frame-based stereotactic biopsy (STB) lacks intraoperative visual control. Augmented reality (AR) via Microsoft HoloLens 2 offers real-time visualization of the biopsy needle. This study evaluates the technical feasibility and preliminary clinical results of AR navigation during standard frame-based STB. METHODS: This prospective single-center pilot study included 10 adults undergoing STB for intracranial lesions. Standard trajectory planning utilized the Cosman-Roberts-Wells (CRW®) stereotactic frame, intraoperative computed tomography (CT), and preoperative magnetic resonance imaging (MRI) in NeuroSight Arc®. Concurrently, Medgital software and HoloLens 2 displayed a hologram of the patient's head, lesion, and trajectory. A passive tracker on the biopsy needle enabled real-time holographic visualization. Endpoints included technical feasibility, registration time, navigation error, diagnostic yield, and complications. RESULTS: AR navigation feasibility was confirmed in all 10 patients (100%). Mean registration time was 79 ± 27 s, and mean AR trajectory error relative to standard planning was 2.21 ± 0.67 mm. A definitive histological diagnosis was obtained in all 10 cases (mean passes: 2.4). No hemorrhagic complications or mortality occurred. CONCLUSION: Integrating AR navigation (HoloLens 2 and Medgital) with conventional frame-based STB is potentially technically feasible, safe, fast, and provides acceptable accuracy. AR complements the standard workflow by offering direct intraoperative visualization of the needle trajectory.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of augmented reality for interstitial brachytherapy optimisation: a prospective phantom-based study protocol and preliminary results.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
- Comparison of the Image-to-Patient Registration Performance of a Novel Augmented Reality-Based and a State-of-the-Art Infrared Optical Neuronavigation System.Operative neurosurgery (Hagerstown, Md.) · 2026
- Clinical accuracy and efficiency of augmented reality head-mounted displays in cranial neurosurgery: a systematic reviewThe Egyptian Journal of Neurology, Psychiatry and Neurosurgery · 2026
- Advancing neurosurgical practice with augmented reality: a single-center real-world case series with illustrated technical notes.Neurosurgical focus · 2026
- Markerless augmented reality guidance for mastoidectomy: a phantom feasibility study using a head-mounted displayFrontiers in Virtual Reality · 2026
- SURG-11 Comparison of Frame-Based and Frameless Robot-Assisted BiopsyNeuro-Oncology · 2026