Markerless augmented reality guidance for mastoidectomy: a phantom feasibility study using a head-mounted display
Yang Li, Tristan Putzeys, Carlos Rodríguez-Guerrero, Nicolas Verhaert
Key points
From the paper's conclusion- Markerless augmented reality (AR) provides non-disruptive guidance by overlaying 3D anatomy directly onto the surgical view.
Abstract
Introduction Cochlear implantation requires precise mastoid drilling to avoid facial nerve injury. Markerless augmented reality (AR) provides non-disruptive guidance by overlaying 3D anatomy directly onto the surgical view. Methods We developed a markerless AR system using a Magic Leap 2 head-mounted display. Preoperative CT models are coloured for RGB matching. In the proposed pipeline, the Segment Anything Model 3 and FoundationPose automatically achieve six-degree-of-freedom (6-DOF) registration of the anatomy without fiducials or external trackers (instrument tracking remains marker-based). Registration was evaluated on the intact bone surface before drilling. Results Across nine sessions spanning three working distances and three viewing angles, the mean lateral target registration error was 1.56 ± 1.01 mm in magnitude (root-mean-square 1.82 mm), with a rotational error of 0.86° ± 0.28°. Depth deviation averaged 6.90 ± 3.41 mm and fell steadily as working distance increased, while no statistically significant effect of viewing angle was detected. Measured directly in image space, without HMD-based visual alignment, the in-plane registration error was about 2 mm and nearly constant across all conditions; this analysis does not estimate depth, so the source of the depth error remains unresolved. Mean measured software-pipeline latency was 153 ms, excluding sensor-to-application delay and display buffering. A single cadaveric specimen provided a preliminary demonstration that registration is maintained on natural bone under partial occlusion. Discussion This markerless system, using a single wearable sensing and display device with off-board processing, demonstrates low-millimetre lateral accuracy for preoperative registration. Despite the observed depth error, it offers a non-invasive, ergonomic alternative to traditional trackers for projecting vital otologic structures; clinical evaluation and continuous registration through bone removal are the next steps towards intraoperative navigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical accuracy and efficiency of augmented reality head-mounted displays in cranial neurosurgery: a systematic reviewThe Egyptian Journal of Neurology, Psychiatry and Neurosurgery · 2026
- Accuracy of Video Optical See-Through Augmented Reality Surgical System (VOSTARS) to Guide Craniotomy: A Phantom and a Human Cadaver Study.Brain sciences · 2026
- Augmented reality versus three-dimensionally printed guides in Le Fort I osteotomy: a preclinical study.International journal of oral and maxillofacial surgery · 2026
- Comparison of the Image-to-Patient Registration Performance of a Novel Augmented Reality-Based and a State-of-the-Art Infrared Optical Neuronavigation System.Operative neurosurgery (Hagerstown, Md.) · 2026
- Wearable Augmented Reality for Dental Implant Navigation: From Experimental Models to Clinical Application-A Scoping Review.Dentistry journal · 2026
- Comparative analysis between optical see-through and video see-through technologies: usability and accuracy assessment of two head-mounted displays for cranio-maxillofacial surgeryVirtual Reality · 2026