Comparison of the Image-to-Patient Registration Performance of a Novel Augmented Reality-Based and a State-of-the-Art Infrared Optical Neuronavigation System.
Tessa M Kos, Wouter D Maathuis, Peter W A Willems, Lambertus W Bartels, Pierre A Robe, Tristan P C van Doormaal
Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands. · Department of Neurosurgery and Neurology, University Medical Center Utrecht, Utrecht, The Netherlands.
Key points
From the paper's conclusion- Comparable registration performance was observed in the phantom measurements. A statistically significant difference in the registration performance of the 2 systems was observed in the patient measurements. The difference between the phantom and clinical findings highlights that similar registration performance can be achieved by the 2 systems under controlled circumstances, but the effect of clinical variables on the registration performance requires further investigation.
Abstract
BACKGROUND AND OBJECTIVES: Augmented reality-based neuronavigation systems (AR-NS) have been proposed as a potential addition to regular neuronavigation systems, such as optical or electromagnetic systems. Accurate image-to-patient registration is a prerequisite for clinical acceptance and implementation of AR-NS in neurosurgical workflows. In this study, the registration performance of a novel AR-NS using a head-mounted display with an integrated red-green-blue camera was compared with that of a state-of-the-art infrared optical neuronavigation system. The performance was evaluated in controlled phantom experiments and in a clinical setting, focusing on registration error, localization precision, and registration time. METHODS: Phantom experiments were performed using a human head model equipped with 8 fiducial markers under controlled conditions. Subsequently, adult patients who were undergoing cranial neurosurgery with preoperative T1-weighted contrast-enhanced MRI were included in the clinical study. In both phantom and clinical settings, the target registration error (TRE) and fiducial registration error were assessed using 7 registration fiducials and one independent target fiducial. The registration time was also recorded. Paired t-tests were used for the statistical analysis. RESULTS: Data from 37 patients were included for analysis. In phantom experiments, sub-3-mm TRE and sub-1-mm point localization were achieved with both systems (P = .63). In the clinical setting, mean TRE values for AR-NS and infrared optical neuronavigation system were 5.5 ± 3.0 mm [95% CI: 4.8, 6.2] and 4.0 ± 2.0 mm [95% CI: 3.4, 4.7], respectively. The mean TRE difference was 1.2 ± 3.6 mm [95% CI: 0.1, 2.4], P = .047. CONCLUSION: Comparable registration performance was observed in the phantom measurements. A statistically significant difference in the registration performance of the 2 systems was observed in the patient measurements. The difference between the phantom and clinical findings highlights that similar registration performance can be achieved by the 2 systems under controlled circumstances, but the effect of clinical variables on the registration performance requires further investigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical accuracy and efficiency of augmented reality head-mounted displays in cranial neurosurgery: a systematic reviewThe Egyptian Journal of Neurology, Psychiatry and Neurosurgery · 2026
- Markerless augmented reality guidance for mastoidectomy: a phantom feasibility study using a head-mounted displayFrontiers in Virtual Reality · 2026
- Accuracy of Video Optical See-Through Augmented Reality Surgical System (VOSTARS) to Guide Craniotomy: A Phantom and a Human Cadaver Study.Brain sciences · 2026
- Application of augmented reality in frame-based stereotactic brain biopsy: a case series feasibility study.Journal of neuro-oncology · 2026
- Augmented Reality Navigation in Perpendicular Plate of Ethmoid Bone Resection: A Teaching Practice.Aesthetic plastic surgery · 2026
- Accuracy of Augmented Reality-Guided Angular Trajectories in Spine Surgery: A Cadaveric Study Comparing 2D-3D vs Intraoperative Computed Tomography Registration.International journal of spine surgery · 2026