Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation.
Peize Wang, Kun Zhang, Jinlong Bai, Xiuhong Dong, Shuai Yang, Lichao Tian, Zhaoqian Zhang, Zhi Li,
TEDA International Cardiovascular Hospital, Tianjin, China. · TEDA International Cardiovascular Hospital, Tianjin, China. 33757883@qq.com.
Key points
From the paper's conclusion- The primary results of this study demonstrate the safety and effectiveness of the balloon-based PFA system for performing PVI in patients with PAF.
Abstract
AIMS: Pulsed field ablation (PFA) is a ablation modality that is increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients. This study assessed the safety and effectiveness of a balloon-based PFA system at 6 months after treatment. METHODS AND RESULTS: This study is a prospective, single-center, premarket study. A total of 56 patients with drug-refractory paroxysmal atrial fibrillation (PAF) were enrolled between November 2024 and September 2025 and underwent PVI with a balloon-based PFA system. The study endpoints were the rate of primary serious adverse events, acute procedural effectiveness and 6-month freedom from recurrence. Acute effectiveness was achieved in 100% (231/231) of the treated PVs (100% of patients, 56/56), with 33 ± 5.5 PFA applications/patient. The procedure, fluoroscopy, and transpired ablation times were 89.0 ± 30.7, 24.2 ± 8.3, and 20.0 ± 12.0 min, respectively. One (1.8%; 1/56) primary serious adverse event occurred: one patient developed intraoperative gastrointestinal bleeding due to TEE-induced mechanical injury. One patient developed a cerebral infarction on postoperative Day 28. The rate of freedom from documented atrial arrhythmias was 92.9% through 6 months after the index procedure. CONCLUSION: The primary results of this study demonstrate the safety and effectiveness of the balloon-based PFA system for performing PVI in patients with PAF.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- First-in-human experience and one-year outcomes using a novel conformal pulsed-field ablation balloon catheter for pulmonary vein isolation in paroxysmal atrial fibrillation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
- Asymmetric biphasic pulsed field ablation of paroxysmal atrial fibrillation: clinical assessment.Frontiers in cardiovascular medicine · 2026
- Real-World Experience With the Balloon-in-Basket Pulsed Field Ablation System for Pulmonary Vein Isolation and Ablation of Extra-Pulmonary Vein Sites.Journal of cardiovascular electrophysiology · 2026
- Safety, Efficacy, and Effectiveness of Pulsed Field Ablation with Farapulse™ to Treat Atrial Fibrillation: A Prospective Single-center Study.The Journal of innovations in cardiac rhythm management · 2026
- Safety and Effectiveness of a Novel Dual-Energy Radiofrequency/Pulsed Field Ablation Catheter: 12 Month Results of the FlexPulse Study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Safety and effectiveness of a mid-voltage pulsed-field ablation catheter in persistent atrial fibrillation: acute outcomesEuropean Heart Journal · 2026