Asymmetric biphasic pulsed field ablation of paroxysmal atrial fibrillation: clinical assessment.
Xinyu Xu, Yunfan Li, Fengmin Lu, Huanming Li, Heng Cai
School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, China. · Department of Cardiology, Tianjin Chest Hospital, Tianjin, China.
Key points
From the paper's conclusion- Conclusions This asymmetric biphasic PFA system achieved complete acute PVI and 12-month effectiveness was within the range reported in previous studies of PFA technologies.
Abstract
BACKGROUND: Pulsed field ablation (PFA) is a non-thermal, tissue-selective therapy for atrial fibrillation. In this study, we evaluated the safety and efficacy of a novel asymmetric biphasic PFA system, which combines a unique pulse-parameter configuration with a dedicated, adjustable six-spline catheter. METHODS: This prospective, multicenter, single-arm study was conducted in China. Patients with drug-refractory paroxysmal AF underwent pulmonary vein isolation (PVI) using a 1,000 V asymmetric biphasic PFA system with a novel parameter configuration. The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence through 12 months post-blanking. The primary safety endpoint was predefined serious adverse events. The secondary safety endpoint was hemolysis and silent cerebral lesions (SCLs). RESULTS: Among 120 enrolled patients, 105 underwent ablation and completed the 12-month follow-up, while 15 patients withdrew before the PFA operation. Acute PVI was successfully achieved in all 420 targeted veins. At 12 months, the Kaplan-Meier estimate of freedom from atrial arrhythmia recurrence was 69.5% (95% CI, 60.1-77.5%). The observed 12-month effectiveness was within the range reported in previous studies of PFA technologies. Regarding safety, major procedural complications-including pulmonary vein stenosis, phrenic nerve injury, atrioesophageal fistula, stroke, and acute kidney injury (AKI)-were entirely absent. However, one patient (0.95%) experienced a transient coronary vasospasm that was successfully resolved with an intracoronary vasodilator. Additionally, SCLs were detected in two patients (1.9%). While laboratory hemolysis was a common finding, it did not lead to renal impairment. CONCLUSIONS: This asymmetric biphasic PFA system achieved complete acute PVI and 12-month effectiveness was within the range reported in previous studies of PFA technologies. It showed a favorable safety profile, with few SCLs and no hemolysis-related AKI. CLINICAL TRIAL REGISTRATION: https://www.chictr.org.cn/showproj.html?proj=134973, identifier ChiCTR2200062157.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pulsed field vs radiofrequency ablation for paroxysmal atrial fibrillation: the BEAT PAROX-AF trialEuropean Heart Journal · 2026
- Outcomes With Pulsed Field Ablation Versus Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation: A Meta‐AnalysisJournal of Arrhythmia · 2025
- Pulsed Field Ablation Versus Thermal Ablation for Paroxysmal Atrial Fibrillation: A GRADE-Assessed Systematic Review and Meta-Analysis of Randomized Controlled Trials With Reconstructed Time-to-Event Analysis.Cardiology in review · 2026
- Pulsed Field Ablation for Atrial Fibrillation: Mechanism, Clinical Evidence, and Emerging Applications.Cureus · 2026
- Pulsed field ablation versus conventional thermal ablation for atrial fibrillation: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Pulsed field versus thermal ablation for atrial fibrillation: a systematic review and meta-analysis of efficacy, safety and procedural performanceEuropean Heart Journal · 2026