Quantitative assessment of corneal haze: comparative optical densitometry using anterior segment OCT and Pentacam.

Miklós Ágoston Lukács, László Módis

Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Nagyerdei Krt. 98, 4032, Debrecen, Hungary. lukacs.miklos@med.unideb.hu. · Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Nagyerdei Krt. 98, 4032, Debrecen, Hungary.

Key points

From the paper's conclusion
  • Both Pentacam and OCT could provide quantitative data on corneal transparency, but changes in optical densitometry by Pentacam were more prominent and consistent in each slit-lamp grade. The two tomographs demonstrated strong correlations in corneal densitometry and consistently similar values in anterior surface astigmatism and central corneal thickness.

Abstract

PURPOSE: Corneal densitometry (CD) is an objective method for the evaluation of corneal opacities. The aim of this study was to compare corneal densitometry along with other tomographic values obtained by two different tomographs in various corneal pathologies. METHODS: Tomography was performed on 59 corneal opacities of 46 patients and on 26 healthy corneas of 13 age-matched controls using optical coherence tomography (OCT) (ANTERION, Heidelberg Engineering GmbH, Heidelberg, Germany) and Scheimpflug tomography (Pentacam AXL, OCULUS Optikgeräte GmbH, Wetzlar, Germany). Pentacam densitometry values were calculated using the built-in software, whereas OCT-based values were obtained from four cross-sectional images of each cornea, with the average grayscale unit (GSU) value measured using ImageJ. Tomographic pachymetry, anterior surface astigmatism, slit-lamp grading and best corrected visual acuity (BCVA) were also recorded. RESULTS: Densitometry values measured by Pentacam were significantly greater in the corneal haze group compared to controls within the entire cornea (36.51 ± 10.65 GSU vs. 20.30 ± 6.27 GSU; p < 0.001) and the central 2 mm zone (44.19 ± 16.69 GSU vs. 16.55 ± 3.44 GSU; p < 0.001) as well. OCT-based densitometry demonstrated significantly greater value only within the central zone (34.98 ± 3.81 GSU vs. 32.16 ± 4.41 GSU; p < 0.014), but not within the entire cornea (28.99 ± 3.26 GSU vs. 27.50 ± 2.93 GSU, p = 0.149). Significantly higher astigmatism was measured by both tomographs in the haze group (4.07 ± 5.06 D vs. 0.69 ± 0.49 D and 3.27 ± 3.22 D vs. 0.72 ± 0.52 D, p < 0.001). Pachymetry measurements yielded no significant differences. Furthermore, similar astigmatism and central corneal thickness were measured within each group by the two devices. BCVA was 0.44 ± 0.31 in the haze group which negatively correlated with densitometry (- 0.447, p < 0.001). Densitometry values obtained with the two tomographs were significantly correlated (r = 0.851, p < 0.001). CONCLUSION: Both Pentacam and OCT could provide quantitative data on corneal transparency, but changes in optical densitometry by Pentacam were more prominent and consistent in each slit-lamp grade. The two tomographs demonstrated strong correlations in corneal densitometry and consistently similar values in anterior surface astigmatism and central corneal thickness.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Quantitative assessment of corneal haze: comparative optical densitometry using anterior segment OCT and Pentacam — Science Skim