Application of volumetric absorptive microsampling (VAMS) for the simultaneous determination of cadmium and lead in blood.
Claus Gutknecht, Alexandra Burianova, Stephan Bose-O'Reilly, Stefan Rakete
Institute and Clinic for Occupational, Social and Environmental Medicine, LMU University Hospital, LMU Medicine, LMU Munich, Ziemssenstraße 1, 80336, Munich, Germany. · Institute and Clinic for Occupational, Social and Environmental Medicine, LMU University Hospital, LMU Medicine, LMU Munich, Ziemssenstraße 1, 80336, Munich, Germany. stefan.rakete@med.uni-muenchen.de.
Key points
From the paper's conclusion- This study evaluates the applicability of volumetric absorptive microsampling (VAMS) as an alternative sampling method for biomonitoring of Cd and Pb in human blood.
Abstract
Cadmium (Cd) and lead (Pb) are toxic elements. This study evaluates the applicability of volumetric absorptive microsampling (VAMS) as an alternative sampling method for biomonitoring of Cd and Pb in human blood. VAMS and blood samples were collected from 60 participants using untreated VAMS. Furthermore, samples from additional 27 participants were collected using VAMS pre-cleaned with 0.5% (v/v) nitric acid to reduce background levels in VAMS and improve performance. All samples were extracted (VAMS) or diluted (venous blood) with 0.5% (v/v) nitric acid prior to analysis by ICP-MS. For untreated VAMS, geometric mean (GM) recovery was 106.2% for Cd and 102.8% for Pb. For pre-cleaned VAMS, GM recovery was 117.2% for Cd and 104.6% for Pb. A strong correlation (Spearman Rho) between both methods was found (Cd, ρ = 0.84; Pb, ρ = 0.93). Correlation improved (Cd, ρ = 0.91; Pb, ρ = 0.98) for pre-cleaned VAMS. For untreated VAMS, the limits of quantification (LOQ) were 0.42 µg/l for Cd and 15.3 µg/l Pb. Pre-cleaning of VAMS led to a 90% background reduction for Pb (0.35 µg/l vs 3.61 µg/l). Background of Cd was unaffected by pre-cleaning (0.05 µg/l vs 0.07 µg/l). LOQs for pre-cleaned VAMS were 0.45 µg/l for Cd and 2.10 µg/l for Pb. Despite challenges like the background, VAMS is a promising alternative sampling method for human biomonitoring of Cd and Pb in blood. This study demonstrates the benefits of washing VAMS to reduce background.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of volumetric DBS for lead analysis using ICP-MS/MS: addressing matrix effects and hematocrit variability.Bioanalysis · 2026
- Rapid quantification of environmental pollutant metals in dried blood spots via direct microextraction coupled to ICP-MS (μEx-ICP-MS).Talanta · 2026
- B-336 ICP MS analysis of cellulose based microsamples containing 10 or 50 µL of bloodClinical Chemistry · 2026
- RPLC- and HILIC-based non-targeted metabolomics workflow for blood microsamplesMetabolomics · 2026
- LC-MS/MS quantification of trimethylamine N-oxide in plasma and volumetric absorptive microsamples: analytical validation and feasibility in pediatric kidney transplant recipients.Clinica chimica acta; international journal of clinical chemistry · 2026
- Point-of-care sensing technologies for urinary lead detection: A systematic review.Talanta · 2026