Rapid quantification of environmental pollutant metals in dried blood spots via direct microextraction coupled to ICP-MS (μEx-ICP-MS).
Cameron J Stouffer, R Kenneth Marcus
Department of Chemistry, Biosystems Research Complex, Clemson University, Clemson, SC, 29634-0973, USA. · Department of Chemistry, Biosystems Research Complex, Clemson University, Clemson, SC, 29634-0973, USA. Electronic address: marcusr@clemson.edu.
Key points
From the paper's conclusion- Inductively coupled plasma-mass spectrometry (ICP-MS) is the predominant technique for DBS heavy metal analysis, yet the complexity of the blood matrix often complicates direct analysis.
Abstract
Dried blood spot (DBS) sampling is a valuable method in clinical analysis due to its minimally invasive nature, reduced sample volume requirements, and simple storage conditions. DBS analysis is of specific interest in assessing exposure to medically relevant heavy metals, such as cadmium (Cd), mercury (Hg), and lead (Pb). However, the limited sample volume presents analytical challenges, particularly for low-concentration analytes, necessitating a highly sensitive and selective detection method. Inductively coupled plasma-mass spectrometry (ICP-MS) is the predominant technique for DBS heavy metal analysis, yet the complexity of the blood matrix often complicates direct analysis. After extraction of the sample from the substrate via acid digestion or ashing, chromatographic separations and additional pre-treatment steps are frequently required before MS detection, resulting in time-consuming workflows. To address these issues, we present an alternative DBS analysis approach utilizing the Advion Plate Express microextraction device (μEx-ICP-MS) for direct sampling with minimal sample preparation. This method enables rapid (<4 min), sensitive (sub to low μg L-1 detection limits), and multi-element profiling of DBS substrates. In this approach, a ∼2 × 4 mm region of the DBS sample is exposed to an extraction solvent, efficiently removing adsorbed species with direct delivery to the ICP nebulizer. The use of aqueous calibration standards for Cd, Hg, and Pb in real human blood samples provides matrix matched quantification. Additionally, studies examining sample extraction reproducibility and metal recovery from standard samples are presented. This method offers a streamlined, accessible approach for microextraction from DBS substrates and elemental detection in clinical analyses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Multitarget Screening Method for the Detection of Small Peptides in Dried Blood Spots for Doping Control AnalysisDrug Testing and Analysis · 2026
- Development and Validation of an LC-MS/MS Method for the Determination of Pesticides in Dried Blood Spots: Optimization of Extraction and Analytical Performance.Biomolecules · 2026
- B-336 ICP MS analysis of cellulose based microsamples containing 10 or 50 µL of bloodClinical Chemistry · 2026
- Application of volumetric absorptive microsampling (VAMS) for the simultaneous determination of cadmium and lead in blood.Environmental monitoring and assessment · 2026
- Evaluation of volumetric DBS for lead analysis using ICP-MS/MS: addressing matrix effects and hematocrit variability.Bioanalysis · 2026
- From urine to serum: blood-based matrices reshape the future of anti-doping testing.Bioanalysis · 2026