Point-of-care sensing technologies for urinary lead detection: A systematic review.

Chonnikarn Jirasit, Jira Kongpran, Udomratana Vattanasit, Yin Nyein Myat, Siriwan Kantisin

Department of Environmental Health and Technology, School of Public Health, Walailak University, Nakhon Si Thammarat, Thailand; Excellent Center on Public Health Research (EC for PHR), School of Public Health, Walailak University, Tha Sala, 80160, Thailand. Electronic address: Chonnikarn.jir@gmail.com. · Department of Environmental Health and Technology, School of Public Health, Walailak University, Nakhon Si Thammarat, Thailand; Excellent Center on Public Health Research (EC for PHR), School of Public Health, Walailak University, Tha Sala, 80160, Thailand.

Review

Key points

From the paper's conclusion
  • This systematic review, following PRISMA 2020 guidelines, searched PubMed, Scopus, and Web of Science (January 2010-October 2026) to identify and appraise POC and biosensor-based technologies for urinary Pb2+ detection.

Abstract

Lead (Pb2+) exposure remains a major global public health concern, and urinary lead measurement provides a non-invasive biomarker for occupational and population biomonitoring. Reference methods such as ICP-MS and AAS are accurate but are unsuitable for point-of-care (POC) use. This systematic review, following PRISMA 2020 guidelines, searched PubMed, Scopus, and Web of Science (January 2010-October 2026) to identify and appraise POC and biosensor-based technologies for urinary Pb2+ detection. Of 714 records identified, 32 studies met the inclusion criteria. Classified by sensing mechanism, 15 used voltammetric, one potentiometric, 11 colorimetric/optical, and five fluorescence detection; device format (e.g., paper-based, screen-printed, or single-use devices) was analyzed separately. Reported limits of detection ranged from 0.0002 to 131 μg/L, and 28 studies reported an LOD at or below a 20 μg/L screening benchmark. However, only ten determined the LOD in urine, and only 22 had a linear range that included the benchmark. Most platforms gave a result within 30 min, but readout and sample handling limited field use: only five combined a time to result of ≤30 min with an instrument-free or camera-based readout, and only two of these were tested in real urine. Urine validation relied mainly on spike recovery, single volunteers, synthetic urine, or high-level certified materials. Stability was reported in eight studies, and creatinine correction in only one. Analytical sensitivity is therefore no longer the main barrier. Translation now requires urine-based figures of merit, validation in exposed populations against reference methods, integrated sample handling with creatinine correction, and field-deployable readout.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers