Environmental geochemistry and health

Environmental radiological baseline characterization of a proposed medical cyclotron facility in Indonesia using dual-detector measurements and geostatistical analysis.

Dikdik Sidik Purnama, Dani Muliawan, Muhayatun Santoso, Rian Fitriana, Eka Djatnika Nugraha, Adi Rahmansyah Amir Abdullah, Sidik Permana

Doctoral Program in Nuclear Engineering, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology (ITB), Jl. Ganesha No. 10, Bandung, 40132, West Java, Indonesia. dikdik.sidik.purnama@brin.go.id. · Directorate of Nuclear Facility Management, National Research and Innovation Agency (BRIN), Jl. Tamansari No. 71, Bandung, 40132, West Java, Indonesia.

Key points

From the paper's conclusion
  • The findings establish a site-specific pre-operational radiological baseline and demonstrate a transferable framework integrating measurement validation, uncertainty analysis, and spatial modelling for environmental surveillance around planned radiological facilities.

Abstract

Establishing a robust pre-operational radiological baseline is essential for distinguishing pre-existing environmental variability from changes associated with future nuclear medicine operations. This study characterizes the ambient gamma-radiation field at a proposed medical cyclotron facility in South Cikarang, West Java, Indonesia. Nineteen monitoring locations were designated across heterogeneous terrain, with direct measurements obtained at 18 locations because Point B was unavailable. Ambient dose equivalent rates, H*(10), were measured at the ground surface and 1 m above ground level using complementary Geiger-Müller (GM) and NaI(Tl) detectors, with ten replicate measurements per configuration. Across all detector systems and measurement heights, H*(10) ranged from 0.030 to 0.120 µSv h-1, and median surface-to-1 m reductions were 11.8% for GM and 14.2% for NaI(Tl). Inter-detector agreement was strong, with Pearson r = 0.958 at the surface and 0.919 at 1 m. Ordinary Kriging identified spatial dependence over approximately 100 m, with higher values associated with engineered sand and crushed-stone fill and lower values generally associated with natural clay-dominated and vegetated ground. Screening-level annual external dose estimates ranged from 0.052 to 0.172 mSv y-1 and excess lifetime cancer risk from 1.76 × 10-4 to 5.86 × 10-4. The findings establish a site-specific pre-operational radiological baseline and demonstrate a transferable framework integrating measurement validation, uncertainty analysis, and spatial modelling for environmental surveillance around planned radiological facilities.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers