Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Radiometric survey and baseline natural radioactivity assessment in the future Ilha Verde Municipal Environmental Protection Area (APA), Rio de Janeiro, Brazil.

R B Pinheiro, J L Thalhofer, A X Silva, L Carvalheira, T S Cunha, E M Souza

Postgraduate Program in Environmental Science and Technology (PPGCTA/UERJ), State University of Rio de Janeiro, Rio de Janeiro, 23070-200, Brazil. Electronic address: prof.rodrigopinheiro@gmail.com. · Department of General Biology (Laboratory of Radiobiology and Radiometry - LARARA) and Postgraduate Program in Dynamics of Oceans and Earth (PPGDOT), Federal Fluminense University (UFF), São Domingos, Niterói, RJ, 24210-201, Brazil. Electronic address: jardellt@id.uff.br.

Key points

From the paper's conclusion
  • These findings establish a preliminary radiometric baseline for the monitored public-use sectors, providing reference data for future environmental monitoring and comparative radiological assessments.

Abstract

The future Ilha Verde Municipal Environmental Protection Area (APA), located in Mangaratiba, Rio de Janeiro, Brazil, comprises a former quarry underlain by granitic lithologies. An in-situ survey was conducted to establish a preliminary baseline of outdoor ambient dose equivalent rate, in sectors planned for public use. Measurements were performed at 17 accessible locations at 1.0 m above ground level using a GQ GMC-500+ Geiger-Müller detector calibrated at an ISO/IEC 17025-accredited laboratory. Point-mean values ranged from 0.14 to 0.20 μSv/h, with an overall mean of 0.17 μSv/h, a spatial standard deviation of 0.02 μSv/h, and a 95% confidence interval for the mean of approximately 0.16-0.18 μSv/h. Using an outdoor occupancy factor of 0.2 and as a screening operational proxy for effective dose, the mean annual outdoor effective-dose estimate was approximately 0.30 mSv/y and the corresponding mean ELCR was 1.04 × 10-3. These modeled quantities are screening indicators and are not direct measurements of individual effective dose or health outcome. These findings establish a preliminary radiometric baseline for the monitored public-use sectors, providing reference data for future environmental monitoring and comparative radiological assessments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers