Clinical utility of pupil diameter cutoffs for detecting early presbyopia.
Kate Gettinger, Akiko Hanyuda, Miyuki Kubota, Shunsuke Kubota, Sachiko Masui, Masahiko Ayaki, Kazuno Negishi
Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan. · Department of Ophthalmology, Shonan Keiiku Hospital, Kanagawa, Japan.
Key points
From the paper's conclusion- A difference in pupil diameter of 0.95mm could be the optimal cutoff value for assessing early presbyopia. As pupil dynamics have been previously related to presbyopia, this study proposes threshold pupil diameter measurement values to provide an alternative practical way to clinically screen for and assess presbyopia.
Abstract
PURPOSE: Little data exist on clinically relevant pupil diagnostic values for detecting early presbyopia (accommodative amplitude [AA]< 2.50D). This study aimed to determine the optimal cutoff value of pupil diameters for screening early presbyopia. STUDY DESIGN: Cross-sectional observational study METHODS: 115 individuals aged ≥20 with visual acuity ≥20/25 who had attended one of two healthcare facilities in Japan between December 2020 and December 2021 were included. AA and near and distance pupillary diameters were measured by auto kerato-refractometer (ARK-1s; NIDEK Co.). Optimal cutoff values for early presbyopia were determined by receiver operating characteristic plots based on the Youden index. RESULTS: Among the pupil-related parameters (near or distance alone, or the difference between these), the difference between near and distance pupil diameters of 0.95 mm yielded the best results, with 82.4% sensitivity and 82.9% specificity (AUC 0.87). CONCLUSION: A difference in pupil diameter of 0.95mm could be the optimal cutoff value for assessing early presbyopia. As pupil dynamics have been previously related to presbyopia, this study proposes threshold pupil diameter measurement values to provide an alternative practical way to clinically screen for and assess presbyopia.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Axial Length to Corneal Curvature Ratio is Insufficient for Detecting Pseudomyopia in Children: A Multi-Cohort Study.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Pupillary Diameter and Image Count in Telemedicine ROP Parameter Classification.Ophthalmology. Retina · 2026
- A comparative analysis of pupillometry measurements obtained from different devices featuring static and dynamic capabilities.Documenta ophthalmologica. Advances in ophthalmology · 2026
- Association Between Pseudoaccommodation Measured With the Salzburg Reading Desk Versus the Reading Chart in Pseudophakic Patients.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Visual Performance of Two Daily Disposable Multifocal Contact Lenses in Presbyopic Soft Lens Wearers.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Dynamic pupillometry in patients with visible optic disc drusen: a cross-sectional study.BMC ophthalmology · 2026