Axial Length to Corneal Curvature Ratio is Insufficient for Detecting Pseudomyopia in Children: A Multi-Cohort Study.
Huyen T Bui, Dirk J van Hemert, Tianli Peng, Shuhui Yang, Hai-Yen T Nguyen, Hannah Noor, Siofra C Harrington, Sander C M Kneepkens,
School of Optometry & Vision Sciences, Cardiff University, Cardiff, UK. · Department of Ophthalmology, Erasmus MC University Medical Centre, Rotterdam, The Netherlands.
Key points
From the paper's conclusion- Despite moderate diagnostic performance in European samples, the current AL/CR-based models lacked sufficient accuracy for screening and performed poorly in East Asian children, suggesting that AL/CR is not a reliable non-cycloplegic marker of pseudomyopia. Further studies incorporating additional ocular biometric parameters and employing a more rigorous definition of pseudomyopia may build on these initial findings.
Abstract
PURPOSE: Pseudomyopia is an accommodative disorder that can be identified by the difference between pre- and post-cycloplegic refractive error. The current study aimed to evaluate whether the axial length to corneal curvature (AL/CR) ratio, in conjunction with non-cycloplegic refractive error, can reliably identify pseudomyopia in children, thus avoiding the need for cycloplegia. METHODS: Refractive error and biometry data from longitudinal studies based in Denmark (n = 645; age 7-17 years) and China (Anyang Childhood Eye Study; n = 2487; age 6-13 years) were used to train separate linear mixed models for children of European or East Asian ancestry, respectively, with AL/CR ratio as outcome and cycloplegic spherical equivalent refractive error (SER), age and sex as predictors. The models could be used to calculate the AL/CR 95% prediction interval in a child of known age, sex and non-cycloplegic SER; if the child's AL/CR fell below the lower limit of the AL/CR 95% prediction interval, then the child was classified as pseudomyopic. The European and East Asian models were externally validated using data from participants of the Ireland Eye Study (IES; n = 92) and Sydney Myopia Study (SMS; n = 686) cohorts, and the Hong Kong Children Eye Study (HKCES; n = 9519) and Vietnam (n = 1165) cohorts, respectively. RESULTS: The European model demonstrated moderate detection accuracy for pseudomyopia: sensitivity = 0.82 (IES) and 0.81 (SMS); specificity = 0.75 in both cohorts. By contrast, the East Asian model performed poorly: sensitivity = 0.22 (HKCES) and 0.13 (Vietnam); specificity = 0.99 in both cohorts. CONCLUSIONS: Despite moderate diagnostic performance in European samples, the current AL/CR-based models lacked sufficient accuracy for screening and performed poorly in East Asian children, suggesting that AL/CR is not a reliable non-cycloplegic marker of pseudomyopia. Further studies incorporating additional ocular biometric parameters and employing a more rigorous definition of pseudomyopia may build on these initial findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Corneal radius-specific axial length/corneal radius ratio cut-offs for improved myopia detection in children: a population-based study.The British journal of ophthalmology · 2026
- Three-year cohort study on the predictive role of axial length-to-corneal radius ratio in the incidence and progression of myopia among Chinese schoolchildren.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Targeted Cycloplegia in Refractive Screening of Children and Adolescents: Development and Internal Validation of a Pre-Cycloplegia Risk Prediction Model - 10 PLADs, China, 2020-2024.China CDC weekly · 2026
- Virtual control arms for paediatric myopia trials: external validation of axial-elongation modelsmedRxiv · 2026
- Influence of Refractive Error on Astigmatism Progression Patterns in Chinese Preschool Children.Ophthalmic epidemiology · 2026
- Machine Learning-Based Prediction of Cycloplegic Refraction Using the Eyerobo Vision Screener: Design-A Cross-Sectional Comparative Device Study.Ophthalmology and therapy · 2026