A magnetic separation-assisted fluorescent aptasensor based on CdTe QDs and Ag⁺ for clinical serum detection of FABP3 in acute myocardial infarction.
Qi Jiao, Zhisong Wang, Qiuqian Gu, Yijing Tao, Ping Zou, Qianwen Yao, Juan Wang
Department of Cardiology, Changshu Hospital Affiliated to Soochow University, Changshu No.1 People's Hospital, Changshu, 215500, China. · Department of Cardiology, Changshu Hospital Affiliated to Soochow University, Changshu No.1 People's Hospital, Changshu, 215500, China. 13862240766@163.com.
Key points
From the paper's conclusion- The results showed good agreement with a commercial ELISA kit (R² = 0.98), with a mean bias of -0.16 ng/mL and 95% limits of agreement from - 1.70 to + 1.39 ng/mL.
Abstract
A magnetic separation-assisted competitive fluorescent aptasensor based on CdTe quantum dots (CdTe QDs) and Ag⁺ for the sensitive and selective detection of heart-type fatty acid binding protein (FABP3) in clinical serum samples has been developed. CdTe QDs were first quenched by Ag⁺ to form a CdTe QDs-Ag⁺ complex in the off state. The aptamer was immobilized on magnetic beads and hybridized with poly-T to form an MB-Apt/poly-T duplex. In the presence of FABP3, the aptamer preferentially bound to FABP3, leading to the release of poly-T from the magnetic beads. After magnetic separation, the released poly-T in the supernatant bound to Ag⁺ and competed with CdTe QDs for Ag⁺, thereby removing Ag⁺ from the CdTe QDs surface and restoring the fluorescence of CdTe QDs. In the absence of FABP3, poly-T remained on the magnetic beads, and the supernatant showed no fluorescence recovery. Under optimized conditions, the sensor exhibited a linear response to FABP3 in the range 1-20 ng/mL, with a detection limit of 0.087 ng/mL. The method also showed excellent selectivity toward FABP3 against other interfering substances. In clinical serum samples, the sensor successfully distinguished healthy individuals from patients with myocardial injury. The results showed good agreement with a commercial ELISA kit (R² = 0.98), with a mean bias of -0.16 ng/mL and 95% limits of agreement from - 1.70 to + 1.39 ng/mL. Recoveries were 97.2-104.3% in 20% serum.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tetrahedral DNA Framework-Bridged Aptasensing Method for Ultrasensitive Determination of Cardiac Troponin I.Chemical & biomedical imaging · 2026
- A magnetic separation-assisted signal-off fluorescence aptasensor for trace profenofos detection.Mikrochimica acta · 2026
- A Hyperbranched Rolling Circle Amplification Assay Using Aptamer-Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB.ACS measurement science au · 2026
- An Ultrasensitive Fluorescent Immunoassay Based on R-CDs@SiO2 Nanoparticles for Detection of Cardiac Troponin I.Applied biochemistry and biotechnology · 2026
- Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction.ACS sensors · 2026
- A fluorescence aptasensor for high sensitivity detection of Golgi protein 73 based on N, S-GQDs and MoS2@RGO via fluorescence resonance energy transfer mechanism.Nanomedicine : nanotechnology, biology, and medicine · 2026