Surgical endoscopy

Image-guided navigation with electromagnetic tracking during robot-assisted partial nephrectomy.

Marijn A J Hiep, Harald C Groen, Wouter J Heerink, Laura Aguilera Saiz, Lisanne P J Venix, Enzo Kerkhof, Axel Bex, Niels M Graafland,

Department of Surgical Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands. ma.hiep@nki.nl. · Department of Surgical Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.

Observational · n=20

Key points

From the paper's conclusion
  • IGN during RAPN is technically feasible and may enhance intraoperative tumor margin identification for precise resections, but wireless sensors and clinical evaluation in more complex, completely endophytic renal tumors are required in future.

Abstract

BACKGROUND: The aim of robot-assisted partial nephrectomy (RAPN) is complete tumor resection while maximally preserving healthy renal parenchyma. Image-guided navigation (IGN) provides real-time intraoperative guidance, which might be beneficial for endophytic margin assessment and resection of renal lesions. This study evaluates the technical feasibility and accuracy of IGN with electromagnetic tracking during RAPN. METHODS: In this prospective feasibility study, 20 patients scheduled for RAPN were included from June 2024 to November 2025. During RAPN, tracked intraoperative ultrasound was used to align a patient-specific three-dimensional model with the kidney. This enabled real-time navigation of tracked surgical instruments relative to planned resection margins and automatic augmented reality visualization. We assessed the ability to achieve preoperatively planned resection volumes using IGN by computing the planned and resected tumor volume difference. Secondary outcomes were the navigation accuracy at the tumor, study measurement time, and usability of the IGN setup using the system usability scale (SUS). RESULTS: In 70% (14/20) of the patients, the planned and resected volume difference was below 35%, indicating technical feasibility of the IGN technique. The median navigation accuracy was 2.2 (IQR 1.9-5.4) mm, the mean ± SD measurement time was 11 ± 3 min, and the median SUS score was 68 (IQR 65-70). Limitations of this study were wired sensors, one surgeon completed all SUS questionnaires, and limited clinical applicability in low-complex, exophytic tumors. CONCLUSION: IGN during RAPN is technically feasible and may enhance intraoperative tumor margin identification for precise resections, but wireless sensors and clinical evaluation in more complex, completely endophytic renal tumors are required in future.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Image-guided navigation with electromagnetic tracking during robot-assisted partial nephrectomy — Science Skim