Trackerless Augmented Reality Navigation for Robotic Partial Nephrectomy using Simultaneous Localization and Mapping.
Jayender Jagadeesan, Emily Huang, Haoyin Zhou, Nathaniel Hansen, Nnamdi Ogugua Onochie, Timothy N Clinton, Christopher P Dall, Matthew Mossanen,
Key points
From the paper's conclusion- A trackerless SLAM-based navigation system, evaluated retrospectively on recorded operative video, demonstrates the feasibility of accurate augmented visualization during partial nephrectomy.
Abstract
PURPOSE: To evaluate the performance of a novel trackerless surgical navigation system for partial nephrectomy using 3D laparoscopy integrated with the simultaneous localization and mapping (SLAM) algorithm. MATERIALS AND METHODS: Patients undergoing robotic partial nephrectomy were retrospectively analyzed. From the preoperative CT/MR images, three-dimensional (3D) models of the kidney, tumor, and vasculature were generated using a deep learning-based approach. A calibrated stereo laparoscope acquired stereo video, which was processed using the SLAM algorithm to reconstruct high-fidelity 3D surface models of the kidney. This reconstruction was registered to the preoperative kidney model using anatomical landmarks and surface-based alignment. Augmented overlays of anatomy, including the tumor, were projected onto the surgical view. Accuracy was assessed using surface target registration error (STRE), landmark registration error (LRE), and localization error. A multi-institutional surgeon survey evaluated the trackerless navigation system using 10 representative cases. RESULTS: Twenty patients undergoing robotic partial nephrectomy were analyzed. Dense 3D surface reconstruction and laparoscope calibration were successful in all cases. Mean (SD; range) STRE, LRE, and localization errors were 1.47 (0.5; 0.6-2.5) mm, 4.3 (1.6; 1.1-6.5) mm, and 2.6 (1.2; 0.7-5.2) mm, respectively. Nine surgeons highly rated the 3D and 2D overlays (3.99 and 4.41/5). Reported cognitive load was moderate (2.38), with high scores for anatomical accuracy (4.44), trust in the overlay for intraoperative decision-making (3.89), and likelihood of adoption (4.56) on a 5-point scale. CONCLUSIONS: A trackerless SLAM-based navigation system, evaluated retrospectively on recorded operative video, demonstrates the feasibility of accurate augmented visualization during partial nephrectomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of deep learning-based surface reconstruction and tracking of surgical scenes for minimally invasive intervention.Proceedings of SPIE--the International Society for Optical Engineering · 2026
- Precise and minimally invasive localization of pelvic nodes during robot-assisted surgery using image-guided navigation.International journal of computer assisted radiology and surgery · 2026
- RAUL: Reference-Assisted Ureteroscopy Localization for Skill AssessmentarXiv · 2026
- SLAM‐Based Real‐Time Endoscope Localization Via SfM‐MVS Reconstruction and Cross‐Source Point Cloud Registration for Robotic Spinal SurgeryThe International Journal of Medical Robotics and Computer Assisted Surgery · 2026
- Iterative trocar-constrained laparoscope viewpoint search for enhanced surface coverage in 3D reconstruction.Scientific reports · 2026
- Camera calibration and tracking for augmented reality during robotic surgery.International journal of computer assisted radiology and surgery · 2026