Journal of robotic surgery

Three-dimensional guidance and AI-assisted navigation in robot-assisted partial nephrectomy: a function-based scoping review.

Chen-Yue Liu, Jun-Dong Zhao, Ming-Ze Sun, Gong-Lin Tang, Hong-Wei Zhao

The Second Clinical Medical School, Shandong Medical and Pharmaceutical University, Yantai, Shandong, China. · Shandong Second Medical University Clinical Medical College, Weifang, China.

Review

Key points

From the paper's conclusion
  • We included 122 reports: 78 clinical, 23 technical, 19 indirect, and two protocols.

Abstract

Complex robot-assisted partial nephrectomy requires vascular clamping, deep tumor localization, and preservation of functional renal tissue. Patient-specific three-dimensional models may inform these decisions, but planning, model display, and spatially registered navigation provide different information and require distinct validation. Artificial intelligence (AI)-assisted initial matching does not establish reliable continuous navigation. These distinctions are essential to assessing decision support and clinical benefit. To map demonstrated guidance functions and surgical decisions in robot-assisted partial nephrectomy, distinguish model display from spatially validated navigation, and link each function to proximal endpoints, reliability measures, and patient outcomes. We searched PubMed/MEDLINE, IEEE Xplore, OpenAlex, and Embase through 21 September 2026, screening 800 unique records and assessing 126 full reports. We mapped functions and validation evidence report by report, classifying other evidence separately without pooling effects. We included 122 reports: 78 clinical, 23 technical, 19 indirect, and two protocols. Of 78 clinical reports, 58 described planning or display without verified spatial registration. Vascular-planning studies reported clamping changes or branch concordance. Two mixed-reality randomized trials reported shorter warm ischemia without demonstrated renal-function benefit; a virtual-reality trial did not improve its primary operative-time endpoint. No completed trial isolated sustained AI-assisted navigation. Evidence most directly supports vascular planning and operative orientation. Claims that registered or AI-assisted overlays improve resection require validation of target-specific accuracy during organ movement, detection of registration failure, and effects on renal and oncological outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers