European radiology

Multicenter prospective study comparing ultra-low-dose CT, conventional radiography, and standard-dose CT for fracture detection in traumatology.

Maxime Pastor, Chris Serrand, Wissem Nabi, Oumaya Ben Said, Djamel Dabli, Patrick Omoumi, Jean-Paul Beregi, Joël Greffier

IMAGINE University of Montpellier, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France. · IDESP, University of Montpellier, Nîmes University Hospital, Nîmes, France.

Observational

Key points

From the paper's conclusion
  • ULD-CT demonstrated higher sensitivity than CR for fracture detection, with similar specificity, using standard-dose CT as the reference.

Abstract

OBJECTIVES: To compare the diagnostic performance of ultra-low-dose CT (ULD-CT) and conventional radiography (CR) for fracture detection in trauma patients, using standard-dose CT (STD-CT) as the reference. MATERIALS AND METHODS: This prospective study on diagnostic accuracy was conducted at five centers from October 2019 to September 2023 and included adult participants with suspected fractures of the extremities, pelvis/hip, or thoracolumbar spine. All participants underwent CR, ULD-CT, and STD-CT during the same visit. Blinded radiologists independently assessed fractures and associated abnormalities. Sensitivity, specificity, accuracy, radiation dose, image quality, and interpretation time were evaluated. RESULTS: Five hundred and thirty-three participants (mean age, 52 ± 22 years; 283 women) were evaluated, including 282 (53%) with fractures. For fracture detection, CR yielded 201 out of 282 true positives (sensitivity: 71% [65-76%]) and 81 out of 282 false negatives (29%), compared with 269 out of 282 true positives (sensitivity: 95% [92-98%]) and 13 out of 282 false negatives (5%) with ULD-CT (p < 0.01). Specificity was 242 out of 251 (96% [93-98%]) for CR and 245 out of 251 (98% [95-99%]) for ULD-CT (p = 0.58). ULD-CT showed higher sensitivity for both articular (154 of 171 (90%) vs. 93 of 171 (54%); p < 0.001) and soft-tissue abnormalities related to trauma (287 of 315 (91%) vs. 184 of 315 (58%); p < 0.001). Effective dose (E) was lower with ULD-CT than with STD-CT (p < 0.01) but higher than with CR, except for distal extremities (p = 0.33). CONCLUSION: ULD-CT demonstrated higher sensitivity than CR for fracture detection, with similar specificity, using standard-dose CT as the reference. KEY POINTS: Question Can ultra-low-dose CT (ULD-CT) improve detection of fractures and associated traumatic abnormalities compared with conventional radiography (CR) while maintaining high diagnostic confidence? Findings ULD-CT showed significantly higher sensitivity than CR for fractures, articular injuries, and soft-tissue abnormalities, with similar specificity. Clinical relevance ULD-CT increased diagnostic confidence and improved detection of fractures and associated traumatic abnormalities compared with CR, potentially reducing missed injuries and the need for additional imaging examinations despite slightly longer interpretation times.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers